Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Development and Validation of Analytical Method for Clopidogrel Bisulphate and Irbesartan by Simultaneous Equation Spectroscopic Method


Affiliations
1 Department of Quality Assurance, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India
2 Department of Pharmacognosy, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India
     

   Subscribe/Renew Journal


A simple, accurate and precise spectroscopic method was developed for simultaneous estimation of Clopidogrel Bisulphate and Irbesartan in synthetic mixture using simultaneous equation Method. In this spectroscopic method, for Clopidogrel Bisulphate 220.00 nm and 250.00 nm wavelengths were selected for measurement of absorptivity. Both the drugs show linearity in a concentration range of 10-50 μg/ml at their respective λmax with correlation coefficient (r2) of 0.9996 and 0.9998 for Clopidogrel Bisulphate and Irbesartan, respectively. Accuracy, precision and recovery studies were done by QC samples covering lower, medium and high concentrations of the linearity range. The relative standard deviation for accuracy, precision studies were found to be within the acceptance range (< 2%). The limit of determination was 0.243 μg/ml and 0.323 μg/ml for Clopidogrel Bisulphate and Irbesartan, respectively. The limit of quantification was 0.737 μg/ml and 0.980 μg/ml for Clopidogrel Bisulphate and Irbesartan, respectively. Recovery of Clopidogrel Bisulphate and Irbesartan were found to be 99.57 % and 99.68 % respectively confirming the accuracy of the proposed method. % Assay was found to be 99.41 % and 99.22 % for Clopidogrel Bisulphate and Irbesartan, respectively. The proposed method is recommended for routine analysis since they are rapid, simple, accurate and also sensitive and specific by no heating and no organic solvent extraction.

Keywords

Clopidogrel Bisulphate, Irbesartan, Simultaneous Estimation, Validation Method.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 191

PDF Views: 2




  • Development and Validation of Analytical Method for Clopidogrel Bisulphate and Irbesartan by Simultaneous Equation Spectroscopic Method

Abstract Views: 191  |  PDF Views: 2

Authors

Pankaj Savani
Department of Quality Assurance, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India
Sudhanshu Chauhan
Department of Quality Assurance, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India
Vineet Jain
Department of Pharmacognosy, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India
Hasumati Raj
Department of Quality Assurance, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India
Sagar Patel
Department of Quality Assurance, Shree Dhanvantary Pharmacy College, Kim, Dist: Surat, Gujarat 394110, India

Abstract


A simple, accurate and precise spectroscopic method was developed for simultaneous estimation of Clopidogrel Bisulphate and Irbesartan in synthetic mixture using simultaneous equation Method. In this spectroscopic method, for Clopidogrel Bisulphate 220.00 nm and 250.00 nm wavelengths were selected for measurement of absorptivity. Both the drugs show linearity in a concentration range of 10-50 μg/ml at their respective λmax with correlation coefficient (r2) of 0.9996 and 0.9998 for Clopidogrel Bisulphate and Irbesartan, respectively. Accuracy, precision and recovery studies were done by QC samples covering lower, medium and high concentrations of the linearity range. The relative standard deviation for accuracy, precision studies were found to be within the acceptance range (< 2%). The limit of determination was 0.243 μg/ml and 0.323 μg/ml for Clopidogrel Bisulphate and Irbesartan, respectively. The limit of quantification was 0.737 μg/ml and 0.980 μg/ml for Clopidogrel Bisulphate and Irbesartan, respectively. Recovery of Clopidogrel Bisulphate and Irbesartan were found to be 99.57 % and 99.68 % respectively confirming the accuracy of the proposed method. % Assay was found to be 99.41 % and 99.22 % for Clopidogrel Bisulphate and Irbesartan, respectively. The proposed method is recommended for routine analysis since they are rapid, simple, accurate and also sensitive and specific by no heating and no organic solvent extraction.

Keywords


Clopidogrel Bisulphate, Irbesartan, Simultaneous Estimation, Validation Method.