Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Assessment of Commercial Effluents in Reference of Some Selected Parameter of Siltara Industrial Area, Raipur


Affiliations
1 Dept. of Chemistry, Dr. C.V. Raman University, Kargi Road, Kota, Bilaspur, C.G.-495, India
2 Dept. of Biotechnology, Dr. C.V. Raman University, Kargi Road, Kota, Bilaspur, C.G.-495113, India
3 Dept. of Pharmacy, Columbia Institute of Pharmacy, Tekari, Raipur, C.G., India
     

   Subscribe/Renew Journal


Analytical studies of some selected physicochemical parameter were made on the surface and underground water bodies at Siltara industrial area, Raipur. Siltara industrial area is situated 5 km away from the Raipur city, Chhattisgarh. Both surface and underground water samples were collected in the month of October'2010. Temperature, PH, E.C, Salinity, TDS, D.O etc. were analyzed instantly on the sampling spots while T.S, TSS, TH, Alkalinity, D.O, BOD, COD, Cl, SO42−, NO3, Fe etc. were analyzed in the laboratory of pollution Control Board, Bilaspur, C.G. It was observed that Temperature, PH, Alkalinity, TH, DO, BOD, Cl, SO42−, NO3 and Fe have higher value than maximum permissible limit of IS: 10500. The elevated values of these parameters are of great concern to public health when the water from these well, bore well and hand pump are consumed by people without treatment. Commercial effluents polluted both surface and underground water bodies.

Keywords

Physiochemical Property, Commercial Effluent, Surface Water, Underground Water.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 300

PDF Views: 0




  • Assessment of Commercial Effluents in Reference of Some Selected Parameter of Siltara Industrial Area, Raipur

Abstract Views: 300  |  PDF Views: 0

Authors

Milan Hait
Dept. of Chemistry, Dr. C.V. Raman University, Kargi Road, Kota, Bilaspur, C.G.-495, India
Kavita Nag
Dept. of Chemistry, Dr. C.V. Raman University, Kargi Road, Kota, Bilaspur, C.G.-495, India
Shivi Sharma
Dept. of Chemistry, Dr. C.V. Raman University, Kargi Road, Kota, Bilaspur, C.G.-495, India
Sangeeta Sharma
Dept. of Biotechnology, Dr. C.V. Raman University, Kargi Road, Kota, Bilaspur, C.G.-495113, India
Leena Sahu
Dept. of Pharmacy, Columbia Institute of Pharmacy, Tekari, Raipur, C.G., India

Abstract


Analytical studies of some selected physicochemical parameter were made on the surface and underground water bodies at Siltara industrial area, Raipur. Siltara industrial area is situated 5 km away from the Raipur city, Chhattisgarh. Both surface and underground water samples were collected in the month of October'2010. Temperature, PH, E.C, Salinity, TDS, D.O etc. were analyzed instantly on the sampling spots while T.S, TSS, TH, Alkalinity, D.O, BOD, COD, Cl, SO42−, NO3, Fe etc. were analyzed in the laboratory of pollution Control Board, Bilaspur, C.G. It was observed that Temperature, PH, Alkalinity, TH, DO, BOD, Cl, SO42−, NO3 and Fe have higher value than maximum permissible limit of IS: 10500. The elevated values of these parameters are of great concern to public health when the water from these well, bore well and hand pump are consumed by people without treatment. Commercial effluents polluted both surface and underground water bodies.

Keywords


Physiochemical Property, Commercial Effluent, Surface Water, Underground Water.