Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Simultaneous Spectrophotometric Estimation of Ezetimibe and Simvastatin in Bulk and its Combined Dosage Form


Affiliations
1 S.N.Vanitha Pharmacy Mahavidyalaya, Hyderabad, India
     

   Subscribe/Renew Journal


Two simple, sensitive, accurate, precise, rapid and economical methods were developed for the estimation of Ezetimibe and Simvastatin in solid dosage form. First method is based on simultaneous equations and second method is based on absorbance ratio method. Ezetimibe has absorbance maxima at 231.2 nm and Simvastatin has Absorbance maxima at 246.2 nm in methanol. The linearity was obtained in the concentration range 2-10 μg/ml for both Ezetimibe and Simvastatin. In the first method the concentration of the drugs were determined by using simultaneous equations and in second method, concentration of the drugs were determined by using ratio of absorbance at isoabsorptive point and at λ-max of one of the drug. The proposed method was statistically validated and found that it is simple, accurate, precise and suitable for the routine analysis of pharmaceutical formulations.

Keywords

Simultaneous Equations, Absorbance Ratio, Iso-Absorptive Point, Validation.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 232

PDF Views: 1




  • Simultaneous Spectrophotometric Estimation of Ezetimibe and Simvastatin in Bulk and its Combined Dosage Form

Abstract Views: 232  |  PDF Views: 1

Authors

K. R. Sireesha
S.N.Vanitha Pharmacy Mahavidyalaya, Hyderabad, India
K. Prakash
S.N.Vanitha Pharmacy Mahavidyalaya, Hyderabad, India
Poluri Koteswari
S.N.Vanitha Pharmacy Mahavidyalaya, Hyderabad, India
K. Shanta Kumari
S.N.Vanitha Pharmacy Mahavidyalaya, Hyderabad, India

Abstract


Two simple, sensitive, accurate, precise, rapid and economical methods were developed for the estimation of Ezetimibe and Simvastatin in solid dosage form. First method is based on simultaneous equations and second method is based on absorbance ratio method. Ezetimibe has absorbance maxima at 231.2 nm and Simvastatin has Absorbance maxima at 246.2 nm in methanol. The linearity was obtained in the concentration range 2-10 μg/ml for both Ezetimibe and Simvastatin. In the first method the concentration of the drugs were determined by using simultaneous equations and in second method, concentration of the drugs were determined by using ratio of absorbance at isoabsorptive point and at λ-max of one of the drug. The proposed method was statistically validated and found that it is simple, accurate, precise and suitable for the routine analysis of pharmaceutical formulations.

Keywords


Simultaneous Equations, Absorbance Ratio, Iso-Absorptive Point, Validation.