Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Determination of Entacapone in Pharmaceutical Preparations by Liquid Chromatography


Affiliations
1 Hindu College of Pharmacy, Amaravathi Road, Guntur-522002, India
     

   Subscribe/Renew Journal


A reverse phase high performance liquid chromatographic method (HPLC) has been developed for the estimation of entacapone in its dosage forms using C18 column. The mobile phase (acetonitrile and 20 mM potassium dihydrogen phosphate, PH 3.5) was pumped at a flow rate of 1 ml/min in the ratio of 80:20 and the eluents were monitored at 320 nm. The intra- and inter- day variation was found to be less than 2% showing high precision of the assay method. The mean recovery of the drug from the solution containing 200 or 300 μg/ml was 99.66±1.20% indicating high accuracy. The proposed HPLC method may be used for determining entacapone in bulk drug samples or in pharmaceutical dosage forms.

Keywords

Estimation, Entacapone, Tablets and HPLC.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 182

PDF Views: 0




  • Determination of Entacapone in Pharmaceutical Preparations by Liquid Chromatography

Abstract Views: 182  |  PDF Views: 0

Authors

P. Nagaraju
Hindu College of Pharmacy, Amaravathi Road, Guntur-522002, India
D. Narendra
Hindu College of Pharmacy, Amaravathi Road, Guntur-522002, India
P. Jitendra Kumar
Hindu College of Pharmacy, Amaravathi Road, Guntur-522002, India
V. D. N. Srinivas
Hindu College of Pharmacy, Amaravathi Road, Guntur-522002, India
S. V. N. Padma
Hindu College of Pharmacy, Amaravathi Road, Guntur-522002, India

Abstract


A reverse phase high performance liquid chromatographic method (HPLC) has been developed for the estimation of entacapone in its dosage forms using C18 column. The mobile phase (acetonitrile and 20 mM potassium dihydrogen phosphate, PH 3.5) was pumped at a flow rate of 1 ml/min in the ratio of 80:20 and the eluents were monitored at 320 nm. The intra- and inter- day variation was found to be less than 2% showing high precision of the assay method. The mean recovery of the drug from the solution containing 200 or 300 μg/ml was 99.66±1.20% indicating high accuracy. The proposed HPLC method may be used for determining entacapone in bulk drug samples or in pharmaceutical dosage forms.

Keywords


Estimation, Entacapone, Tablets and HPLC.