Stability Indicating RP-HPLC Method for Simultaneous Estimation of Valsartan and Amlodipine in Capsule Formulation


Affiliations
1 Dr. D.Y. Patil Institute of Pharmaceutical Science and Research, Pimpri, Pune-411018, India
2 S. N. Institute of Pharmacy, Pusad, India
     

   Subscribe/Renew Journal


Present work describes a precise, accurate and reproducible Reverse phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of Amlodipine besylate (AMLB) and Valsartan (VAT) on RP C-18 Column (Kromasil, 250×4.6 mm) using acetonitrile:phosphate buffer (0.02M, pH 3.0), (56:44 v/v) as mobile phase at a flow rate of 1.0 ml/min and the detection wavelength was 234 nm. The retention time for AMLB and VAT was found to be 3.07 and 6.20 min, respectively. The method was also applied for the determination of AMLB and VAT in the presence of their degradation products formed under variety of stress conditions. Proposed method was validated for precision, accuracy, linearity range, robustness and ruggedness.

Keywords

Amlodipine Besylate, Valsartan, Reverse Phase High Performance Liquid Chromatography, Stability Indicating Method.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 214

PDF Views: 0




  • Stability Indicating RP-HPLC Method for Simultaneous Estimation of Valsartan and Amlodipine in Capsule Formulation

Abstract Views: 214  |  PDF Views: 0

Authors

S. S. Chitlange
Dr. D.Y. Patil Institute of Pharmaceutical Science and Research, Pimpri, Pune-411018, India
Kiran Bagri
Dr. D.Y. Patil Institute of Pharmaceutical Science and Research, Pimpri, Pune-411018, India
D. M. Sakarkar
S. N. Institute of Pharmacy, Pusad, India

Abstract


Present work describes a precise, accurate and reproducible Reverse phase High Performance Liquid Chromatographic (RP-HPLC) method for simultaneous estimation of Amlodipine besylate (AMLB) and Valsartan (VAT) on RP C-18 Column (Kromasil, 250×4.6 mm) using acetonitrile:phosphate buffer (0.02M, pH 3.0), (56:44 v/v) as mobile phase at a flow rate of 1.0 ml/min and the detection wavelength was 234 nm. The retention time for AMLB and VAT was found to be 3.07 and 6.20 min, respectively. The method was also applied for the determination of AMLB and VAT in the presence of their degradation products formed under variety of stress conditions. Proposed method was validated for precision, accuracy, linearity range, robustness and ruggedness.

Keywords