Surface Treatment of the Secretariat Building, Chandigarh, India Using Selected Concrete Sealers for Protection from Environmental Deterioration
The Secretariat Building is located inside the Chandigarh, Capitol Complex, India. The exterior surface of the building has deteriorated due to weathering effects. The aim of the present study was to assess efficacy of selected protective materials on exposed heritage reinforced concrete surface of the Secretariat Building for restoration. Selected concrete sealers and Evercrete DPS with essential oil of peppermint and eucalyptus were evaluated for UV degradation yellowing test on white cement panels, accelerated ageing test on concrete beams up to 5 years, field trial on the exterior surface of the Secretariat Building up to 38 weeks and test for determining the water absorption on concrete cores (ASTM D 6489-99) up to 4 years. The result reveals that Konex WRA-2318 and La Shield WR Xtra are effective for surface treatment of the Secretariat Building without changing the colour of the surface up to 4 and 2 years respectively.
Keywords
Accelerated Ageing, Concrete Sealer, Environmental Deterioration, Heritage Buildings, Water Absorption.
User
Font Size
Information
- Meli, R. and Rairez, S., Criteria and experiences on structural rehabilitation of stone masonry buildings in Mexico City. Int. J. Archit. Herit., 2007, 1, 3–28.
- Sandbhor, S. and Botre, R., A systematic approach towards restoration of heritage buildings – a case study. Int. J. Res. Eng. Technol., 2013, 2, 229–238.
- Johansson, A., Janz, M., Silfwerbrand, J. and Tragandh, J., Protection of concrete with water repellent agents – what is required to achieve a sufficient penetration depth? In Concrete Repair and Rehabilitation and Retrofitting – II (eds Alexander et al.), 2009, pp. 763–767; ISBN 978-0-415-46850-3.
- Mishra, S. A., Soni, P. and Pandit, R. K., Waterproofing systems in building construction. Int. J. Combined Res. Dev., 2014, 3, 21– 27.
- Roos, M., Koenig, F., Stadtueller, S. and Weyershausen, B., Evolution of silicon based water repellents for modern building protection. In Proceedings of the 5th International Conference on Water Repellent Treatment of Building Materials, 2008, pp. 3–16.
- Verma, R. K. and Chourasia, A., Protection of bio-deteriorated reinforced concrete using concrete sealers. Int. J. Maters Chem. Phys., 2015, 1, 11–19.
- Muhammad, N. Z., Keyvanfar, A., Majid, M. Z. A., Shafaght, A. and Mirza, J., Waterproof performance of concrete: a critical review on implemented approaches. Constr. Build. Mater., 2015, 101, 80–90.
- Medeiros, M. H. F. and Helene, P., Surface treatment of reinforced concrete in marine environment: influence on chloride diffusion coefficient and capillary water absorption. Constr. Build. Mater., 2009, 23, 1476–1484.
- Singh, M. M. and Patwardhan, N. K., Water repellent coating on mud walls. Res. Ind., 1957, 2, 276.
- Zettemoyer, A. C. H. and Hsing, H., Water on organosilane treated silica surfaces. J. Colloid. Interface Sci., 1977, 58, 263–274.
- McGettigen, E., Application mechanism of silane weatherproofers. Concr. Int., 1990, 12, 66–68.
- Aggarwal, L. K., Surface coatings for waterproofing. In Proceedings of the National Workshop on Waterproofing of Buildings, CBRI, Roorkee, 12–13 March 1996.
- Khalid, M., Silicate based waterproofing system for exposed surfaces. In Proceedings of the National Workshop on Waterproofing of Buildings, CBRI, Roorkee, 12–13 March 1996.
- Ibrahim, M., Al-Gahtani, A. S., Maslehuddin, M. and Dakhil, F. H., Use of surface treatment materials to improve concrete durability. J. Mater. Civil Eng. (ASCE), 1999, 11, 36–40.
- Ghoddousi, P., Raiss Ghasemi, A. M. and Parhizkar, T., The effect of concrete quality on performance of surface treatment materials. In Proceedings of the International Conference on Sustainable Construction Materials and Technologies (eds Rudolph, N. et al.), 11–13 June 2007, pp. 78–84.
- Gholamiyan, H., Tarmian, A., Husseini, K. D. and Azadfallah, M., The potential use of organosilane water soluble nano-materials as water vapor diffusion retarders for wood. Maderas-Clenc. Technol., 2012, 12, 43–52.
- Florin, L. T. and Ioan, T., Modern method to waterproofing rehabilitation for building infrastructure. J. Appl. Eng. Sci., 2012, 2, 109–114.
- Dang, Y., Xie, N., Kessel, A., McVey, E., Pace, A. and Shi, X., Accelerated laboratory evaluation of surface treatment for protecting concrete bridge from salt scaling. Constr. Build. Mater., 2014, 55, 128–135.
- Soudki, K. A., Safiuddin, Md., Jeffs, P., Macdonald, G. and Kroker, M., Chloride penetration resistance of concrete sealer and coating system. J. Civil Eng. Manage., 2015, 21, 492–502.
- Verma, R. K. and Devi, D., Studies for antifungal activity of selected concrete sealers on white cement panels. Int. J. Sci. Eng. Technol. Res., 2015, 4, 2081–2087.
- World Weather Information Service – Chandigarh, World Meteorological Organization. Retrieved 29 September 2012; http:// worldweather.wmo.int/en/city.html?cityId=526
- Kumar, A., Shukla, R., Singh, P., Prasad, C. S. and Dubey, N. H., Assessment of Thymus vulgaris L. essential oil as a botanical preservative against post harvest fungal infection of food commodities. Innov. Food Sci. Emerging Technol., 2008, 9, 575–580.
- Standard specification for liquid membrane-forming compounds having special properties for curing and sealing concrete, ASTM C1315, 2011.
- Standard practice for operating fluorescent light apparatus for UV exposure of nonmetallic materials, ASTM G154, 2000.
- Norvaisien, R., Burlingis, A. and Stankevicius, V., Durability tests on paints façade rendering by accelerated ageing. Mater. Sci., 2010, 16, 80–85.
- Standard test method for determining the water absorption of hardened concrete treated with a water repellent coating. ASTM: D 6489, 1999.
- Roshan, S., Water damage evaluation of concrete infrastructure, Dissertation report, University of Texas at Arlington, USA, 2005, p. 51.
- Basheer, P. A. M., Basheer, D. J., Cleland, D. J. and Long, A. E., Surface treatments for concrete: assessment methods and reported performance. Constr. Build. Mater., 1997, 11, 413–429.