Experimental Determination of Statistical Parameters Associated with Uniaxial Compression Behaviour of Brick Masonry
In view of practical significance of the compression behaviour of brick masonry, this article discusses the evolvement of an experimental programme based on a survey of the literature. Also, it is known that large scatter is expected in the mechanical properties of masonry and studies characterizing these statistical variations are scant in India. Using the evolved experimental programme and results of tests conducted, the statistical parameters, namely mean and coefficient of variation (COV) associated with the uniaxial compression behaviour of typical brick masonry used in South India have been determined in this article. For the masonry considered in this study, the mean values of peak compressive stress, strain corresponding to peak stress and elastic modulus are 2.82 MPa, 0.009 and 0.4 GPa respectively. The corresponding values of COV are 0.15, 0.2 and 0.12 respectively. In addition, a trilinear curve has been suggested as an idealized stress-strain relation for the brick masonry used in South India.
Keywords
Clay Brick Masonry, Compressive Strength, Elastic Modulus, Uniaxial Compression, Statistical Parameters.
User
Font Size
Information
- IS:1905–1987 (reaffirmed 2002), Code of practice for structural use of unreinforced brick masonry – guidelines. Bureau of Indian Standards (BIS), New Delhi, 2002.
- Dymiotis, C. and Gutlederer, B. M., Allowing for uncertainties in the modelling of masonry compressive strength. Constr. Build. Mater., 2002, 16(8), 443–452.
- Pande, G. N., Kralj, B. and Middleton, J., Analysis of the compressive strength of masonry given by the equation fk = K(fb′)α( fm)β. Struct. Eng., 1994, 1, 7–12.
- Haller, P., Die technische Eigenschaften von Backstein, Schweizerische Bauzeitung, 1958.
- Sarangapani, G., Venkatarama Reddy, B. V. and Jagadish, K. S., Structural characteristics of bricks, mortar and masonry. J. Struct. Eng. (CSIR-SERC), 2002, 29, 101–107.
- Gumaste, K. S., Nanjunda Rao, K. S., Venkatarama Reddy, B. V. and Jagadish, K. S., Strength and elasticity of brick masonry prisms and wallettes under compression. Mater. Struct., 2007, 40(2), 241–253.
- Naraine, K. and Sinha, S. N., Loading and unloading stress–strain curves for brick masonry. J. Struct. Eng. (ASCE), 1989, 115(10), 7631–7644.
- AlShebani, M. M. and Sinha, S. N., Stress–strain characteristics of brick masonry under uniaxial cyclic loading. J. Struct. Eng. (ASCE), 1999, 125(6), 600–604.
- Kaushik, H. B., Rai, D. C. and Jain, S. K., Uniaxial compressive stress–strain model for clay brick masonry. Curr. Sci., 2007, 92(4), 497–501.
- Freeda Christy, C., Tensing, D. and Mercy Shanthi, R., Experimental study on axial compressive strength and elastic modulus of the clay and fly ash brick masonry. J. Civ. Eng. Constr. Technol., 2013, 4(4), 134–141.
- ASTM C1314-12, Standard test method for compressive strength of masonry prisms. American Society for Testing and Materials, West Conshohocken, USA, 2002.
- BS 5628-1:2005, Code of practice for the use of masonry – Structural use of unreinforced masonry. British Standards Institute, London, UK, 2005.
- Gischolar_main, C. and Larbi, J., The influence of water flow (reversal) on bond strength development in young masonry. Heron, 1999, 44(2), 63–78.
- RILEM TC 127-MS B.4, Measurement of the shear strength index for unit-mortar junction. Mater. Struct., 1996, 29(8), 459–475.
- Hendry, A. W., Structural Masonry, Macmillan Education Ltd, London, UK, 1990.
- Bennett, R. M., Boyd, K. A. and Flanagan, R. D., Compressive properties of structural clay tile prisms. J. Struct. Eng. (ASCE), 1997, 123(7), 920–926.
- MSJC 2002, ACI 530-02/ASCE 5-02/TMS 402-022002 – Building code requirements for masonry structures. Masonry Standards Joint Committee, USA, 2002.
- Dayaratnam, P., Brick and Reinforced Brick Structures, Oxford and IBH, India, 1987.
- Eurocode 6 (ENV 1996-1-1), Design of masonry structures. Part 1-1: General rules for buildings – reinforced and unreinforced masonry.
- European Committee of Standardization (CEN), Brussels, 1996.
- Desayi, P. and Krishnan, S., Equation for the stress–strain curve of concrete. J. Am. Concr. Inst., 1964, 61(3), 345–350.
- Priestley, M. J. N. and Elder, D. M., Stress–strain curves for unconfined and confined concrete masonry. Am. Concr. Inst. J., 1983, 80(3), 192–201.
- Drysdale, R., Hamid, A. and Baker, L., Masonry Structures: Behaviour and Design, The Masonry Society, USA, 1999, 3rd edn.
- ASTM E 122-09, Standard practice for calculating sample size to estimate, with specified precision, the average for a characteristic of a lot or process. West Conshohocken, USA, 2009.
- BS 5628-3:2005, Code of practice for the use of masonry – Materials and components, design and workmanship. British Standards Institute, London, UK, 2005.
- IS:2250-1981 (reaffirmed 2002), Code of practice for preparation and use of masonry mortars. BIS, New Delhi, 2002.
- ASTM C 1552-14, Practice for capping concrete masonry units, related units and masonry prisms for compression testing. West Conshohocken, USA, 2014.
- ASTM E 111-04, Practice for capping concrete masonry units, related units and masonry prisms for compression testing. West Conshohocken, USA, 2004.
Abstract Views: 351