Open Access Open Access  Restricted Access Subscription Access

Biocompatibility Studies of Electron Beam Cured Pressure Sensitive Adhesive Tape for Medical Application


Affiliations
1 Shriram Institute for Industrial Research, 19-University Road, Delhi 110 007, India
2 Vinoba Bhave University, Hazaribag, Jharkhand 825 301, India
 

Polyurethane (PU)-based pressure-sensitive adhesive (PSA) tapes are commonly used during surgery. Such devices made for biomedical applications must be biocompatible and biologically safe while in use in the human body as their ingredients may leach off of a device into an adjacent tissue and can harm the body during or after application. In the present study, various methods required for biocompatibility establishment, e.g. cytotoxicity, irritation and sensitization for a device, have been analysed and presented following suitable specifications. The study also emphasizes on the developmental and curing mechanism of biomedical adhesive tape by electron beam (e-beam) irradiation.
User
Notifications
Font Size

  • ISO 10993-1, Biological evaluation of medical devices-part 1, evaluation and testing in the risk management process, 2009.
  • ISO 10993-2, Biological evaluation of medical devices-part 2, animal welfare requirements, 2006.
  • ISO 10993-5, Biological evaluation of medical devices-part 5, tests for in vitro cytotoxicity, 2009.
  • ISO 10993-10, Biological evaluation of medical devices-part 10, tests for irritation and skin sensitization, 2010.
  • ISO 10993-12, Biological evaluation of medical devices-part 12, sample preparation and reference materials, 2012.
  • Singh, A. K., Mehra, D. S., Niyogi, U. K., Sabharwal S. and Khandal, R. K., Polyurethane based pressure sensitive adhesives (PSAs) using e-beam irradiation for medical application. J. Polym.Material., 2011, 28(4), 525–542.
  • Singh, A. K., Mehra, D. S., Niyogi, U. K., Sabharwal, S. and Khandal, R. K., Effect of tackifier and crosslinkers on electron beam curable polyurethane pressure sensitive adhesive. Radiat.Phys. Chem., 2012, 81(5), 547–552.
  • Singh, A. K., Mehra, D. S., Niyogi, U. K., Sabharwal, S., Swiderska, J., Czech, Z. and Khandal, R. K., Effect of crosslinkers on adhesion properties of electron beam curable polyurethane pressure sensitive adhesive. Int. J. Adhes. Adhes., 2013, 41, 73– 79.
  • Singh, A. K., Niyogi, U. K., Sabharwal, S., Kowalczyk, A., Czech, Z. and Mehra, D. S., Shrinkage studies in electron beam curable polyurethane pressure sensitive adhesive. J. Adhes. Sci. Technol., 2013, 27(14), 1511–1524.
  • Singh, A. K., Mehra, D. S., Niyogi, U. K., Sabharwal, S. and Singh, G., Breathability studies of electron beam curable polyurethane pressure sensitive adhesive for bio-medical application.Radiat. Phys. Chem., 2014, 103, 75-83.
  • Singh, A. K., Mehra, D. S., Niyogi, U. K., Sabharwal, S. and Singh, G., Life performance evaluation of electron beam-curable polyurethane pressure-sensitive adhesive tape for medical applications.J. Adhes. Sci. Technol., 2014, 28(12), 1192–1206.
  • Fournier, E., Passirani, C., Montero-Menei, C. N. and Benoit, J. P., Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility. Biomater, 2003, 24(19), 3311–3331.
  • Lebowitz, M. D., Key concepts: chemical sensitization. In Multiple Chemical Sensitivities, National Academic Press, Washington, 1992.
  • Turner-Warwick, M., On observing patterns of airflow obstruction in chronic asthma. Br. J. Dis. Chest., 1977, 71, 73–86.
  • Berg, T., Boman, D. and Seglen, P. O., Induction of tryptophan oxidase in primary rat liver cell suspensions by glucocorticoid hormone. Ex. Cell Res., 1972, 72, 571–574.
  • Edmondson, J. M., Armstrong, L. S. and Martinez, A. O., A rapid and simple MTT-based spectrophotometric assay for determining drug sensitivity in monolayer cultures. J. Tiss. Cult. Meth., 1988, 11, 15–17.
  • Mosmann, T., Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays. J.Immun. Method., 1983, 65, 55–63.
  • Lonnroth, E.-C. and Dahl, J. E., Cytotoxicity of dental glass ionomers evaluated using dimethylthiazol diphenyltetrazolium and neutral red tests. Acta. Odontol. Scand., 2001, 59, 34–39.
  • Lonnroth, E.-C. and Dahl, J. E., Cytotoxicity of liquids and powders of chemically different dental materials using dimethylthiazol diphenyltetrazolium and neutral red tests. Acta. Odontol. Scand., 2003, 61, 52–56.
  • Borenfreund, E. and Puerner, J. A., A simple quantitive procedure using monolayer cultures for cytotoxicity assays. J. Tissue Cult. Methods, 1984, 1, 7–9.
  • Wennberg, A., In vitro assessment of the biocompatibility of dental materials – the Millipore filter method. J. Int. End., 1988, 21, 1–5.
  • Lönnroth, E. C., Toxicity of medical glove materials: a pilot study. Int. J. Occup. Saf. Ergo., 2005, 11(2), 131–139.
  • Matsuzaki, A., Yamashita, M. and Hara, N., Effect of pretreatment film composition on adhesion of organic film on zinc coated steel sheet. Mater. Trans., 2010, 51(10), 1833–1841.
  • Amaral, A., Roos, A., Asua, J. M. and Creton, C., Assessing the effect of latex particle size and distribution on the rheological and adhesive properties of model waterborne acrylic pressure-sensitive adhesives films. J. Colloid Inter. Sci., 2005, 281, 325–338.
  • Park, S., Adam Strömstedt, A. A. and Göransson, U., Cyclotide structure–activity relationships: qualitative and quantitative approaches linking cytotoxic and anthelmintic activity to the clustering of physicochemical forces. PLoS ONE, 2014, 9(3), e91430.
  • Lee, Y. J., Lee, G., Kang, S. W., Cheong, Y. and Park, Y.-K., Label-free and quantitative evaluation of cytotoxicity based on surface nanostructure and biophysical property of cells utilizing AFM. Micron, 2013, 49, 54–59.
  • Neilson, L., Mankus, C., Thorne, D., Jackson, D., DeBay, J. and Meredith, C., Development of an in vitro cytotoxicity model for aerosol exposure using 3D reconstructed human airway tissue; application for assessment of e-cigarette aerosol. Toxicol. In Vitro, 2015, 29(7), 1952–1962.
  • McNamara, K., Kolaj-Robin, O., Belochapkine, S., Laffir, F., Gandhi, A. A. and Tofail, S. A. M., Surface chemistry and cytotoxicity of reactively sputtered tantalum oxide films on NiTi plates. Thin Solid Films, 2015, 589, 1–7.
  • Geertsma, R. E., Orzechowski, T. J. H., Jonker, M., Dorpema, J. W. and Asten, J. A. A. M., Radiation vulcanized natural rubber latex: safer than conventionally processed latex? (RIVM report 605148007). Bilthoven, The Netherlands: National Institute for Public Health and the Environment, 1996.
  • Cory, A. H., Owen, T. C., Barltrop, J. A. and Cory, J. G., Use of an aqueous tetrazolium/formazan assay for cell growth assays in culture. Cancer Commun., 1991, 3, 207–212.
  • Lupu, A. R. and Popescu, T., The noncellular reduction of MTT tetrazolium salt by TiO2 nanoparticles and its implications for cytotoxicity assays. Toxicol. In Vitro, 2013, 27(5), 1445–1450.
  • Emter, R. and Natsch, A., A fast Resazurin-based live viability assay is equivalent to the MTT-test in the KeratinoSens assay. Toxicol. In Vitro, 2015, 29(4), 688–693.
  • Ikarashi, Y., Toyoda, K., Oshawa, N., Uchima, T., Tsuchiya, T. and Kaniwa, M., Comparative studies by cell culture and in vivo implantation test on the toxicity of natural rubber latex materials. J. Biomed. Mat. Res., 1992, 26, 339–356.
  • Draize J. H., Woodard, G. and Calvery, G. O., Methods for the study of irritation and toxicity of substances applied topically to the skin and mucous membranes. J. Pharm. Exp. Ther., 1944, 82, 377–390.
  • Casas, J. W., Lewerenz, G. M., Rankin, E. A., Willoughby Sr, J. A., Blakeman, L. C., McKim Jr, K. P. and Coleman, In vitro human skin irritation test for evaluation of medical device extracts. Toxicol. In Vitro, 2013, 27(8), 2175–2183.
  • Pan, T.-L., Wang, P.-W., Aljuffali, I. A., Leu, Y.-L., Hung, Y.-Y. and Fang, J.-Y., Coumarin derivatives, but not coumarin itself, cause skin irritation via topical delivery. Toxicol. Lett., 2014, 226(2), 173–181.
  • Piroird, C., Ovigne J.-M., Rousset, F., Martinozzi-Teissier, S., Gomes, C., Cotovio, J. and Alépée, L., The myeloid U937 skin sensitization test (U-SENS) addresses the activation of dendritic cell event in the adverse outcome pathway for skin sensitization. Toxicol. In Vitro, 2015, 29(5), 901–916.
  • Urbisch, D. et al., Assessing skin sensitization hazard in mice and men using non-animal test methods. Regul. Toxicol. Pharmacol., 2015, 71(2), 337–351.
  • Reisinger, K. et al., Systematic evaluation of non-animal test methods for skin sensitisation safety assessment. Toxicol. In Vitro, 2015, 29(1), 259–270.
  • Nukada, Y., Ashikaga, T., Miyazawa, M., Hirota, M., Sakaguchi, H., Sasa, H. and Nishiyama, N., Prediction of skin sensitization potency of chemicals by human Cell Line Activation Test (h-CLAT) and an attempt at classifying skin sensitization potency. Toxicol. In Vitro, 2012, 26(7), 1150–1160.

Abstract Views: 419

PDF Views: 150




  • Biocompatibility Studies of Electron Beam Cured Pressure Sensitive Adhesive Tape for Medical Application

Abstract Views: 419  |  PDF Views: 150

Authors

Anil Kumar Singh
Shriram Institute for Industrial Research, 19-University Road, Delhi 110 007, India
Gurdeep Singh
Vinoba Bhave University, Hazaribag, Jharkhand 825 301, India

Abstract


Polyurethane (PU)-based pressure-sensitive adhesive (PSA) tapes are commonly used during surgery. Such devices made for biomedical applications must be biocompatible and biologically safe while in use in the human body as their ingredients may leach off of a device into an adjacent tissue and can harm the body during or after application. In the present study, various methods required for biocompatibility establishment, e.g. cytotoxicity, irritation and sensitization for a device, have been analysed and presented following suitable specifications. The study also emphasizes on the developmental and curing mechanism of biomedical adhesive tape by electron beam (e-beam) irradiation.

References