Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

A New Approach to Extract Reference Currents for Three-Level Shunt Active Filter in the Systems Electric


Affiliations
1 Laboratory SCAMRE, Ecole Nationale Polytechnique, Oran BP 1523 El' M'naouer, Oran, Algeria
2 Laboratory LGEGI, University Ibn Khaldoun Tiaret, Algeria
     

   Subscribe/Renew Journal


This paper presents a new approach to Extract Reference Currents for Three-level Shunt Active Filter controlling by fuzzy logic. This active power filters (APFs) are used to compensate harmonic currents generated from the nonlinear loads. The APF is realized using three phase voltage and the carrier-based PWM strategy the latter is used to derive gating signals for the IGBTs. A new approach for identifying reference currents will be developed. It is based on Concordia method using multi-variable filter, and makes the total or selective extraction harmonic currents of references, and by consequence making their compensations, total or selective.

The results of digital simulation in the Matlab-Simulink environment of a system of power PD3 to thyristor outputs on an inductive load show well the effectiveness of this new technique of extraction of the harmonics of reference.


Keywords

Fuzzy Logic Current Controller, Harmonic Current Compensation, Multivariable Filter, Shunt Active Filter, Three-Level (NPC) Inverter.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 263

PDF Views: 3




  • A New Approach to Extract Reference Currents for Three-Level Shunt Active Filter in the Systems Electric

Abstract Views: 263  |  PDF Views: 3

Authors

Abdelkader Yousfi
Laboratory SCAMRE, Ecole Nationale Polytechnique, Oran BP 1523 El' M'naouer, Oran, Algeria
Tayeb Allaoui
Laboratory LGEGI, University Ibn Khaldoun Tiaret, Algeria
Abdelkader Chaker
Laboratory SCAMRE, Ecole Nationale Polytechnique, Oran BP 1523 El' M'naouer, Oran, Algeria

Abstract


This paper presents a new approach to Extract Reference Currents for Three-level Shunt Active Filter controlling by fuzzy logic. This active power filters (APFs) are used to compensate harmonic currents generated from the nonlinear loads. The APF is realized using three phase voltage and the carrier-based PWM strategy the latter is used to derive gating signals for the IGBTs. A new approach for identifying reference currents will be developed. It is based on Concordia method using multi-variable filter, and makes the total or selective extraction harmonic currents of references, and by consequence making their compensations, total or selective.

The results of digital simulation in the Matlab-Simulink environment of a system of power PD3 to thyristor outputs on an inductive load show well the effectiveness of this new technique of extraction of the harmonics of reference.


Keywords


Fuzzy Logic Current Controller, Harmonic Current Compensation, Multivariable Filter, Shunt Active Filter, Three-Level (NPC) Inverter.