Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Design of Four Channel Uniform Filter Bank and Oversampled Three Channels FIR Filter Banks for 2-D Image


Affiliations
1 Electronics and Telecommunication Department, Bharati Vidyapeeth's College of Engg., Kolhapur, India
2 India Society for Technical Education (ISTE), India
     

   Subscribe/Renew Journal


In this paper comparison of four channel uniform critical sampled filter bank with proposed oversampled three channels FIR filter banks [FB] is carried out for two dimensional (2-D ) medical image. Three channels are selected likewise which gives the result near perfect reconstruction filter bank. The inband aliasing is significantly reduced by selecting proper frequency spectrum and design of filters of filter banks. Results of oversampled FIR filter bank and 4-channel uniform filter bank for two dimensional MRI image with energy and histogram of images are compared. By applying wavelet transform energy is preserved at output of oversampled filter banks. Comparison of energy restored at output image of each filter bank with input image energy is carried out. Proposed 3-channel filter bank output gives better results.

Keywords

FIR Filter Bank, Oversampled Filter Bank.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 173

PDF Views: 2




  • Design of Four Channel Uniform Filter Bank and Oversampled Three Channels FIR Filter Banks for 2-D Image

Abstract Views: 173  |  PDF Views: 2

Authors

Sangeeta R. Chougule
Electronics and Telecommunication Department, Bharati Vidyapeeth's College of Engg., Kolhapur, India
R. S. Patil
India Society for Technical Education (ISTE), India

Abstract


In this paper comparison of four channel uniform critical sampled filter bank with proposed oversampled three channels FIR filter banks [FB] is carried out for two dimensional (2-D ) medical image. Three channels are selected likewise which gives the result near perfect reconstruction filter bank. The inband aliasing is significantly reduced by selecting proper frequency spectrum and design of filters of filter banks. Results of oversampled FIR filter bank and 4-channel uniform filter bank for two dimensional MRI image with energy and histogram of images are compared. By applying wavelet transform energy is preserved at output of oversampled filter banks. Comparison of energy restored at output image of each filter bank with input image energy is carried out. Proposed 3-channel filter bank output gives better results.

Keywords


FIR Filter Bank, Oversampled Filter Bank.