Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Design and Development of DSP System for Pulse CO-Oximeter


Affiliations
1 Department of Electronics and Communication Engineering, G.K.M College of Engineering and Technology, Chennai-63, India
2 G.K.M College of Engineering and Technology, India
     

   Subscribe/Renew Journal


A different principles of operation avail for the measurement of heamoglobin. The heamoglobin contain Oxygen binds in red blood cells when moving through the lungs. It is transported throughout the body as arterial blood. Proposed design is a non-invasive hemoglobin measuring system. The method uses principles of pulse-oximeter to measure total hemoglobin, oxygen content, oxygen saturation, reduced Oxyhemoglobin, Carboxyhemoglobin, Pleth Variability Index (PVI), Pulse rate, Perfusion Index (PI) and Methemoglobin. All these parameters in the blood cannot be detected by conventional pulse-oximeter, although it can bias the oximeter’s estimate of the true arterial functional oxygen saturation. This paper depicts a multiple wavelength transmission and photo detecting method adopted to measure total hemoglobin, oxygen content, oxygen saturation and Carboxyhemoglobin. The current method of implementation involves in DSP processor.

Keywords

Anemia, DSP Processor, Heamoglobin, Non-Invasive, Polycythemia.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 168

PDF Views: 1




  • Design and Development of DSP System for Pulse CO-Oximeter

Abstract Views: 168  |  PDF Views: 1

Authors

S. Jegadeesh
Department of Electronics and Communication Engineering, G.K.M College of Engineering and Technology, Chennai-63, India
D. Balasubramaniam
G.K.M College of Engineering and Technology, India

Abstract


A different principles of operation avail for the measurement of heamoglobin. The heamoglobin contain Oxygen binds in red blood cells when moving through the lungs. It is transported throughout the body as arterial blood. Proposed design is a non-invasive hemoglobin measuring system. The method uses principles of pulse-oximeter to measure total hemoglobin, oxygen content, oxygen saturation, reduced Oxyhemoglobin, Carboxyhemoglobin, Pleth Variability Index (PVI), Pulse rate, Perfusion Index (PI) and Methemoglobin. All these parameters in the blood cannot be detected by conventional pulse-oximeter, although it can bias the oximeter’s estimate of the true arterial functional oxygen saturation. This paper depicts a multiple wavelength transmission and photo detecting method adopted to measure total hemoglobin, oxygen content, oxygen saturation and Carboxyhemoglobin. The current method of implementation involves in DSP processor.

Keywords


Anemia, DSP Processor, Heamoglobin, Non-Invasive, Polycythemia.