Mitigating 132kV Transmission Line Outage Due To Lightning Shielding Failure


Affiliations
1 Electrical Engineering at the Rivers State University, Nigeria
2 Department of Electrical and Electronic Engineering, Rivers State University, Nigeria
3 Rivers State University, Nigeria
     

   Subscribe/Renew Journal


132kV Transmission line shielding failure occurs when a lightning stroke escape the sky wire and hit the phase conductor thereby causing induced overvoltage resulting to unplanned outage and possible equipment failure. Considering the economic cost of 132kV transmission line outage on power companies and the inconveniences it has on the energy user, the need for improved protection is of paramount importance. By applying Line Meta-Oxide Surge Arrester along the to damp the overvoltage effect of the shielding failures and Modeling the transmission line using PSCAD-EMTDC 4.5, the lightning response was improved and the lightning overvoltage reduced to its barest minimum hence keeping the line healthy to the benefit of the power companies and the end users.


Keywords

Mitigate, Shielding Failure, Lightning Phenomenon, 132kV, Transmission Line, Meta-Oxide Surge Arrester, PSCAD-EMTDC, Overvoltage.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 219

PDF Views: 1




  • Mitigating 132kV Transmission Line Outage Due To Lightning Shielding Failure

Abstract Views: 219  |  PDF Views: 1

Authors

Gabriel Modukpe
Electrical Engineering at the Rivers State University, Nigeria
D. C. Idoniboyeobu
Department of Electrical and Electronic Engineering, Rivers State University, Nigeria
C. O. Ahiakwo
Rivers State University, Nigeria
S. L. Briade
Department of Electrical and Electronic Engineering, Rivers State University, Nigeria

Abstract


132kV Transmission line shielding failure occurs when a lightning stroke escape the sky wire and hit the phase conductor thereby causing induced overvoltage resulting to unplanned outage and possible equipment failure. Considering the economic cost of 132kV transmission line outage on power companies and the inconveniences it has on the energy user, the need for improved protection is of paramount importance. By applying Line Meta-Oxide Surge Arrester along the to damp the overvoltage effect of the shielding failures and Modeling the transmission line using PSCAD-EMTDC 4.5, the lightning response was improved and the lightning overvoltage reduced to its barest minimum hence keeping the line healthy to the benefit of the power companies and the end users.


Keywords


Mitigate, Shielding Failure, Lightning Phenomenon, 132kV, Transmission Line, Meta-Oxide Surge Arrester, PSCAD-EMTDC, Overvoltage.