Aquifer Transmissivity from Surface Geo-Electrical Data: A Case Study of Owerri and Environs, Southeastern Nigeria


Affiliations
1 Department of Geology, University of Nigeria, Nsukka, Nigeria
2 Department of Geosciences, Federal University of Technology, Owerri, Imo State, Nigeria
     

   Subscribe/Renew Journal


The combination of layer resistivity and thickness in the so called Da-zarrouk parameters S (longitudinal conductance) and R (transverse resistance) have proved useful in the evaluation of the transmissivities of the aquifers around Owerri and environs. The area is underlain by the unconsolidated to semi-consolidated coastal Benin Formation. The surface direct current electrical resistivity method was used in the study. Seven Vertical Electrical Soundings (VES) data by the Schlumberger array was acquired in the area. A maximum current electrode spacing (AB) of 1000 m was used for data acquisition. Four of the soundings were carried out near existing boreholes. Computer modelled interpretative methods was utilized in processing the data. Results show that the depth to the water level is shallow around Ife and Egbu areas with a mean depth of 30 m. Semi-deep aquifers were encountered around Okpalla and AVU areas with a mean depth of 90 m while very deep aquifers were sensed around Owerri and Obinze areas with a mean depth of 125 m. Aquifer thicknesses in the study area range from 8 m at Ife and 117 m at Owerri. The diagnostic Kσ = constant value have proved so useful in calculating transmisivities and hydraulic conductivities of all the sounding locations including areas where no boreholes exist. Hydraulic conductivity varies between 6.19 m/day at Ife and 24.7 m/day at Obinze. Transmissivity values also very between 51.39 m2/day at Ife and 1379.56 m2/day at Owerri. It is hoped that the results would help in long term planning of groundwater exploitation schemes within the study area.

Keywords

Transmissivity, Porous Media, Da-Zarrouk Parameters, Owerri, Southeastern Nigeria.
Subscription Login to verify subscription
User
Notifications
Font Size

  • CHOUDHURY, K., SAHA, D.K. and CHAKRABORTY, P. (2001) Geophysical study for saline water intrusive in a coastal alluvial terrain. Jour. Appld. Geophys., v.46, pp.189-200.
  • EKWE, A.C., ONU, N.N. and ONUOHA, K.M. (2006) Estimation of aquifer hydraulic characteristics from electrical sounding data: the case of middle Imo River basin aquifers, southeastern Nigeria. Jour. Spatial Hydrology, v.6(2), pp.121-132.
  • FROHLICH R.K. and URISH, D. (2002) The use of geoelectrics and test wells for the assessment of ground water quality of a coastal industrial site. Jour. Appld. Geophys., v.50, pp.261-278.
  • JOHNSON, H.K. (1977) A man/computer interpretation system for resistivity soundings over a horizontally stratified earth. Geophysical Prospecting, v.25, pp.667-691.
  • KAYA, G.K. (2001) Investigation of groundwater contamination using electric and electromagnetic methods at an open waste – disposal site: a case study from Isparta, Turkey. Environmental Geol., v.40, pp.725-731.
  • MAILLET, R. (1947) The Fundermental equations of electrical prospecting. Geophysics, v.12, pp.529-556.
  • NIWAS and SINGHAL, D.C. (1981) Estimation of aquifer transmissivity from Dar-Zarronk parameters in porous media.
  • ONU, N.N. (1995) Hydrogeophysical Investigation of the Njaba River; sub-basin south eastern Nigeria, unpublished Ph.D. Thesis, UNN.
  • ONUOHA, K.M. and EZEH, C.C. (1988) Aquifer transmissivity from electrical sounding data. The case of Ajali sand stone aquifers, Southeast of Enugu, Nigeria.
  • Sumanovac, F. and Weisser, M. (2001) Evaluation resistivity and seismic methods for hydrological mapping in Karst terrains. Jour. Appld. Geophys., v.47, pp.13-28.
  • UMA, K.O. (1989) An appraisal of the ground water Resources of the Imo River Basin. Nigerian Jour. Mining and Geol., v.25, nos.1 and 2, pp.305-315.
  • YOUNG, M.E., DE BRUIJIN, R.G.M. and SALIN AL-ISMAILY, A. (1988) Reports: Exploration of an alluvial aquifer in Oman by timedomain electron agnetic sounding, HYDROGEOLOGY Jour., v.6, pp.383-393.
  • Zohdy, A.A.R. (1976) Application of surface Geophysical (electrical methods to groundwater investigations). In: Techniques of water resources investigations of the United States Geological survey, section D, Book 2, pp.5-55.

Abstract Views: 174

PDF Views: 0




  • Aquifer Transmissivity from Surface Geo-Electrical Data: A Case Study of Owerri and Environs, Southeastern Nigeria

Abstract Views: 174  |  PDF Views: 0

Authors

A. C. Ekwe
Department of Geology, University of Nigeria, Nsukka, Nigeria
A. I. Opara
Department of Geosciences, Federal University of Technology, Owerri, Imo State, Nigeria

Abstract


The combination of layer resistivity and thickness in the so called Da-zarrouk parameters S (longitudinal conductance) and R (transverse resistance) have proved useful in the evaluation of the transmissivities of the aquifers around Owerri and environs. The area is underlain by the unconsolidated to semi-consolidated coastal Benin Formation. The surface direct current electrical resistivity method was used in the study. Seven Vertical Electrical Soundings (VES) data by the Schlumberger array was acquired in the area. A maximum current electrode spacing (AB) of 1000 m was used for data acquisition. Four of the soundings were carried out near existing boreholes. Computer modelled interpretative methods was utilized in processing the data. Results show that the depth to the water level is shallow around Ife and Egbu areas with a mean depth of 30 m. Semi-deep aquifers were encountered around Okpalla and AVU areas with a mean depth of 90 m while very deep aquifers were sensed around Owerri and Obinze areas with a mean depth of 125 m. Aquifer thicknesses in the study area range from 8 m at Ife and 117 m at Owerri. The diagnostic Kσ = constant value have proved so useful in calculating transmisivities and hydraulic conductivities of all the sounding locations including areas where no boreholes exist. Hydraulic conductivity varies between 6.19 m/day at Ife and 24.7 m/day at Obinze. Transmissivity values also very between 51.39 m2/day at Ife and 1379.56 m2/day at Owerri. It is hoped that the results would help in long term planning of groundwater exploitation schemes within the study area.

Keywords


Transmissivity, Porous Media, Da-Zarrouk Parameters, Owerri, Southeastern Nigeria.

References