Open Access
Subscription Access
Open Access
Subscription Access
In vitro Dissolution Studies on Commercial Brands Containing Immediate Release Pioglitazone and Metformin Hydrochloride Extended Release Tablets
Subscribe/Renew Journal
The Quality control (QC) tests like weight variation, hardness, friability, drug content, and Invitro dissolution studies were performed for three commercially available brands containing the combination of two anti diabetic drug pioglitazone (15mg) and metformin (500mg) hydrochloride. The dissolution studies were performed in 0.1N hydrochloric acid (pioglitazone HCl) up to 45 minutes and in 6.8 phosphate buffer (metformin HCl) up to 10 hours. The selected formulations satisfied QC requirements. A significant difference in dissolution parameters were noticed from the above brands. The drug dissolution from pioglitazone and metformin hydrochloride marked brand followed first order kinetics and zero order kinetics respectively.
Keywords
Pioglitazone Metformin Combination Comparative Invitro Dissolution Studies.
Subscription
Login to verify subscription
User
Font Size
Information
Abstract Views: 364
PDF Views: 3