Open Access Open Access  Restricted Access Subscription Access

Development of New Solvent System for the Analysis of 2-4 D (Herbicide) Extracted from Blood


Affiliations
1 Department of Forensic Medicine and Toxicology, All India Institute of Medical Sciences, New Delhi-110029, India
2 Department of Ocular Biochemistry, Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi- 110029, India
3 Department of Biotechnology, Lovely Professional University, Phagwara, Punjab- 144402, India
 

2,4-Dichlorophenoxyacetic acid, more commonly referred to as 2,4-D, is an Organochlorus poison which is one of the most widely used herbicides. Several instrumental method like Gas liquid chromatography (GLC), High performance liquid chromatography (HPLC), UV-visible Spectrophotometer, etc., are available for the separation and identification of 2,4-D, but most of them are expensive and more time consuming. So, a relatively inexpensive and less time consuming method is presented for the separation of 2,4-D i.e. Thin Layer Chromatography (TLC). This method has several advantages over the other methods such as its low cost, fewer chemicals required simultaneous analysis of large and low amount of sample. 2,4-D was extracted from the blood and then it was identified by using 20 solvent systems. The spots developed on the TLC plates were developed using Iodine vapors.

Keywords

2,4-D, Organochloro, TLC, RF , Spraying Reagent Etc.
User
Notifications
Font Size

Abstract Views: 268

PDF Views: 162




  • Development of New Solvent System for the Analysis of 2-4 D (Herbicide) Extracted from Blood

Abstract Views: 268  |  PDF Views: 162

Authors

A. K. Jaiswal
Department of Forensic Medicine and Toxicology, All India Institute of Medical Sciences, New Delhi-110029, India
Sunil Kumar
Department of Ocular Biochemistry, Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi- 110029, India
Jeevanjot Kaur
Department of Biotechnology, Lovely Professional University, Phagwara, Punjab- 144402, India
Jasbir Kaur
Department of Ocular Biochemistry, Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi- 110029, India

Abstract


2,4-Dichlorophenoxyacetic acid, more commonly referred to as 2,4-D, is an Organochlorus poison which is one of the most widely used herbicides. Several instrumental method like Gas liquid chromatography (GLC), High performance liquid chromatography (HPLC), UV-visible Spectrophotometer, etc., are available for the separation and identification of 2,4-D, but most of them are expensive and more time consuming. So, a relatively inexpensive and less time consuming method is presented for the separation of 2,4-D i.e. Thin Layer Chromatography (TLC). This method has several advantages over the other methods such as its low cost, fewer chemicals required simultaneous analysis of large and low amount of sample. 2,4-D was extracted from the blood and then it was identified by using 20 solvent systems. The spots developed on the TLC plates were developed using Iodine vapors.

Keywords


2,4-D, Organochloro, TLC, RF , Spraying Reagent Etc.