An Intelligent Software Tool for Avoiding Collision in Complex Radiotherapy Set-ups


Affiliations
1 Department of Electronics, Panacea Medical Technologies Pvt ltd, Banglore, India
2 Department of Mechanical, Panacea Medical Technologies Pvt ltd, Banglore, India
 

Gantry- Couch/ Gantry- Patient collision is a serious problem in various medical equipments in radiotherapy. This collision may cause damage to the machine or even may cause injury to the patient. In this article, an efficient method of avoiding collision that is inherent in the radiotherapy machine is presented. The study uses an intelligent co-ordinate geometry based algorithm for avoiding collision in machines. The overall computation takes less than 0.1 seconds for sensing the collision. Also this new technique for avoiding collision is tested with two different radiotherapy machines namely Imagin and Bhabhatron-II. This is a faster and accurate method of avoiding collisions in complex iso-centric set-ups.

Keywords

Radiotherapy, Collision Detection, Medical Equipment, Complex Radiotherapy Set-ups, Iso-centric
User
Notifications

  • Chiaho Hua, Jenghwa Chang, Kamil Yenice, Maria Chan, and Howard Amols (2004), A practical approach to prevent gantry-couch collision for linac - based radio surgery, Medical Physics, Vol. 31(7), July 2004.
  • I BEANGE and A NISBET (2000), Collision prevention software tool for complex three dimensional iso-centric set up, The British Journal of Radiology.
  • Eli E. Furhang, Joseph Hanley, Sou-Tung Chiu-Tsao, Sean Toner, Pei Fan, Paul Gliedman, and Louis B. Harrison(2002), Clearance assurance for stereotactic radio surgery and radiotherapy, Medical Physics, Vol 29(1), January 2002.
  • Miltiadis F. Tsiakalos, Eduard Schrebmann, Kiki Theodorou and Constantin Kappas (2001),Graphical treatment simulation and automated collision detection for conformal and stereotactic radiotherapy treatment planning, Medical Physics, Vol 28(7), July 2001.
  • http://en.wikipedia.org/wiki/Line-plane_intersection.
  • http://en.wikipedia.org/wiki/Dot_product.

Abstract Views: 621

PDF Views: 345




  • An Intelligent Software Tool for Avoiding Collision in Complex Radiotherapy Set-ups

Abstract Views: 621  |  PDF Views: 345

Authors

K. V. Bineesh
Department of Electronics, Panacea Medical Technologies Pvt ltd, Banglore, India
Ilapakurty Ravi
Department of Electronics, Panacea Medical Technologies Pvt ltd, Banglore, India
G. V. S. Manyam
Department of Mechanical, Panacea Medical Technologies Pvt ltd, Banglore, India

Abstract


Gantry- Couch/ Gantry- Patient collision is a serious problem in various medical equipments in radiotherapy. This collision may cause damage to the machine or even may cause injury to the patient. In this article, an efficient method of avoiding collision that is inherent in the radiotherapy machine is presented. The study uses an intelligent co-ordinate geometry based algorithm for avoiding collision in machines. The overall computation takes less than 0.1 seconds for sensing the collision. Also this new technique for avoiding collision is tested with two different radiotherapy machines namely Imagin and Bhabhatron-II. This is a faster and accurate method of avoiding collisions in complex iso-centric set-ups.