Open Access Open Access  Restricted Access Subscription Access

Comparative Study of Hemodynamic Changes Using Proseal Laryngeal Mask Airway, Intubating Laryngeal Mask Airway or Laryngoscopic Endotracheal Intubation under General Anesthesia in Patients Undergoing Coronary Artery Bypass Grafting Surgery


Affiliations
1 Department of Anesthesiology, SMS Medical College, Jaipur, Rajasthan, India
 

Introduction: Laryngoscopy and endotracheal intubation alter cardiovascular physiology both via reflex responses and physical presence of an endotracheal tube (ETT). Stress response caused by laryngoscopic endotracheal intubation may be harmful for the coronary or cerebral circulation of high‑risk patients. This study aimed to evaluate the hypothesis that placement of Proseal laryngeal mask airway (PLMA) and intubating laryngeal mask airway (ILMA) are associated with less cardiovascular response than the endotracheal intubation via conventional technique. Materials and Methods: In this hospital‑based, randomized, interventional study, 105 patients of the American Society of Anesthesiologists Grade II and III undergoing coronary artery bypass grafting surgery under general anesthesia were randomly allocated into three groups, that is, PLMA, ILMA, and ETT. Hemodynamic parameters such as heart rate, blood pressure, cardiac output, cardiac index, systemic vascular resistance (SVR,) and SVR index baseline, during induction and after insertion of device were compared. Results: The study groups were comparable with respect to age, weight, height, gender, and baseline hemodynamic parameters. The heart rate, systolic blood pressure, diastolic blood pressure, and MAP were significantly higher (P < 0.05) in endotracheal group as compared to PLMA and ILMA groups for 15 min following intubation, that is, throughout the study period. However, there was no significant difference between PLMA and ILMA group (P > 0.05). SVR was significantly higher in endotracheal group as compared to PLMA and ILMA group throughout the study (P < 0.05). The cardiac index at all time was not significantly different among the three groups. Conclusion: PLMA and ILMA insertion is accompanied by minimal cardiovascular responses than those associated with direct laryngoscopic endotracheal intubation, so it can be used for patients in whom a marked pressor response would be deleterious.

Keywords

Coronary artery bypass grafting surgery, intubating laryngeal mask airway, Proseal laryngeal mask airway
User
Notifications
Font Size

Abstract Views: 136

PDF Views: 69




  • Comparative Study of Hemodynamic Changes Using Proseal Laryngeal Mask Airway, Intubating Laryngeal Mask Airway or Laryngoscopic Endotracheal Intubation under General Anesthesia in Patients Undergoing Coronary Artery Bypass Grafting Surgery

Abstract Views: 136  |  PDF Views: 69

Authors

Anjum Saiyed
Department of Anesthesiology, SMS Medical College, Jaipur, Rajasthan, India
Abhishek Jain
Department of Anesthesiology, SMS Medical College, Jaipur, Rajasthan, India
Indu Verma
Department of Anesthesiology, SMS Medical College, Jaipur, Rajasthan, India
Reema Meena
Department of Anesthesiology, SMS Medical College, Jaipur, Rajasthan, India

Abstract


Introduction: Laryngoscopy and endotracheal intubation alter cardiovascular physiology both via reflex responses and physical presence of an endotracheal tube (ETT). Stress response caused by laryngoscopic endotracheal intubation may be harmful for the coronary or cerebral circulation of high‑risk patients. This study aimed to evaluate the hypothesis that placement of Proseal laryngeal mask airway (PLMA) and intubating laryngeal mask airway (ILMA) are associated with less cardiovascular response than the endotracheal intubation via conventional technique. Materials and Methods: In this hospital‑based, randomized, interventional study, 105 patients of the American Society of Anesthesiologists Grade II and III undergoing coronary artery bypass grafting surgery under general anesthesia were randomly allocated into three groups, that is, PLMA, ILMA, and ETT. Hemodynamic parameters such as heart rate, blood pressure, cardiac output, cardiac index, systemic vascular resistance (SVR,) and SVR index baseline, during induction and after insertion of device were compared. Results: The study groups were comparable with respect to age, weight, height, gender, and baseline hemodynamic parameters. The heart rate, systolic blood pressure, diastolic blood pressure, and MAP were significantly higher (P < 0.05) in endotracheal group as compared to PLMA and ILMA groups for 15 min following intubation, that is, throughout the study period. However, there was no significant difference between PLMA and ILMA group (P > 0.05). SVR was significantly higher in endotracheal group as compared to PLMA and ILMA group throughout the study (P < 0.05). The cardiac index at all time was not significantly different among the three groups. Conclusion: PLMA and ILMA insertion is accompanied by minimal cardiovascular responses than those associated with direct laryngoscopic endotracheal intubation, so it can be used for patients in whom a marked pressor response would be deleterious.

Keywords


Coronary artery bypass grafting surgery, intubating laryngeal mask airway, Proseal laryngeal mask airway