Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

IEC 61850 Client Redundancy for Substation Automation System


Affiliations
1 BHEL Corporate Research and Development, India
     

   Subscribe/Renew Journal


This paper presents an overview of System level redundancy implementation in an IEC61850 based Client application and method used to reduce recovery time after failure of the station level application (IEC 61850 Client, HMI and Database). The authors have presented the implementation of a dual Server hot-standby redundancy architecture, Network Driver (NDIS-Network Driver Interface Specification) for heartbeat communication, network teaming for redundant network redundancy and database replication for substation data integrity and availability of substation data/event. This paper also discusses different redundancy modules (Redundancy Manager, IEC 61850 Client Driver, HMI, Database Module) integration like API integration between Network driver (NDIS) and IEC 61850 Client application. The implementation of data queue in IEC 61850 Client to avoid data loss during server switch over is discussed in this paper. The authors have presented the various fail-over mechanisms in this system. As the redundancy has a direct impact on the cost and complexity of the system, the proposed solution in this paper has addressed the needs of application criticality and customer requirements.

Keywords

System level Redundancy, Communications Network Redundancy, Substation Automation System (SAS), HMI, NIC Teaming and IEC 61850
User
Subscription Login to verify subscription
Notifications
Font Size


  • IEC 61850 Client Redundancy for Substation Automation System

Abstract Views: 361  |  PDF Views: 0

Authors

Sudhir Kumar Bai
BHEL Corporate Research and Development, India
Gaurav Kanaujia
BHEL Corporate Research and Development, India

Abstract


This paper presents an overview of System level redundancy implementation in an IEC61850 based Client application and method used to reduce recovery time after failure of the station level application (IEC 61850 Client, HMI and Database). The authors have presented the implementation of a dual Server hot-standby redundancy architecture, Network Driver (NDIS-Network Driver Interface Specification) for heartbeat communication, network teaming for redundant network redundancy and database replication for substation data integrity and availability of substation data/event. This paper also discusses different redundancy modules (Redundancy Manager, IEC 61850 Client Driver, HMI, Database Module) integration like API integration between Network driver (NDIS) and IEC 61850 Client application. The implementation of data queue in IEC 61850 Client to avoid data loss during server switch over is discussed in this paper. The authors have presented the various fail-over mechanisms in this system. As the redundancy has a direct impact on the cost and complexity of the system, the proposed solution in this paper has addressed the needs of application criticality and customer requirements.

Keywords


System level Redundancy, Communications Network Redundancy, Substation Automation System (SAS), HMI, NIC Teaming and IEC 61850

References





DOI: https://doi.org/10.33686/prj.v13i4.189202