Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Realizing the laboratory model for reverse power protection of alternator interfaced with GSM


Affiliations
1 Project Engineer, Wipro Technology Bhubaneswar, India
2 Graduate Engineer Trainee Vedanta Resources PLC Goa, India
     

   Subscribe/Renew Journal


Generators is one of the most important, delicate and costlier components of power system. Since power plant generators are very important part of an electrical energy network, so they should be protected in order to maintain the quality and reliability of power supply. This paper presents the design and implementation of reverse power protection of alternator during the failure of prime mover. Initially the system has been designed by using MATLAB Simulink for synchronous generator and then further implemented in laboratory with the of real time system using reverse power relay interfaced with GSM. The complete analysis of motoring protection system has been constructed on software as well as in hardware and various results have been obtained for the different conditions of prime mover failure.

Keywords

Synchronous generator, motoring protection, reverse power relay, MATLAB/SIMULINK, GSM
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 277

PDF Views: 0




  • Realizing the laboratory model for reverse power protection of alternator interfaced with GSM

Abstract Views: 277  |  PDF Views: 0

Authors

Sumit Srivastava
Project Engineer, Wipro Technology Bhubaneswar, India
Ankit Niranjan
Graduate Engineer Trainee Vedanta Resources PLC Goa, India

Abstract


Generators is one of the most important, delicate and costlier components of power system. Since power plant generators are very important part of an electrical energy network, so they should be protected in order to maintain the quality and reliability of power supply. This paper presents the design and implementation of reverse power protection of alternator during the failure of prime mover. Initially the system has been designed by using MATLAB Simulink for synchronous generator and then further implemented in laboratory with the of real time system using reverse power relay interfaced with GSM. The complete analysis of motoring protection system has been constructed on software as well as in hardware and various results have been obtained for the different conditions of prime mover failure.

Keywords


Synchronous generator, motoring protection, reverse power relay, MATLAB/SIMULINK, GSM



DOI: https://doi.org/10.33686/prj.v13i2.189254