Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Optimal placement and sizing of active power line conditioners


Affiliations
1 PG Scholar, EEE department, Thiagarajar college of engineering, Madurai - 625015, India
2 Assistant Professor, EEE department, Thiagarajar college of engineering, Madurai - 625015, India
     

   Subscribe/Renew Journal


In this paper, a problem of allocation and sizing of multiple active power-line conditioners (aplcs) in power systems is handled with novel formulation. The utilized objective function comprises two main factors such as reduction of total harmonic distortion and the total cost of active power-line conditioners (aplcs). The formulated problem is solved by optimization technique Shuffle Frog Leap Algorithm (SHFLA) using MATLABTM. To evaluate the competence of the proposed formulation, the IEEE 18-bus distorted distribution test system is employed and investigated with various number of aplcs placement. These cases are based on the discrete and limited size for aplcs, requiring the optimization method to solve the constrained and discrete nonlinear problems. The comparison of results in this paper showed that the proposed SHFLA is the most effective result among others in determining optimum location and size of APLC in distribution systems.

Keywords

Active Power-Line Conditioner (APLC),Harmonics,Shuffle Frog Leap Algorithm(SHFLA), Optimal Allocation and Sizing of APLCs (OASA) problem.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 178

PDF Views: 0




  • Optimal placement and sizing of active power line conditioners

Abstract Views: 178  |  PDF Views: 0

Authors

V. Saranya
PG Scholar, EEE department, Thiagarajar college of engineering, Madurai - 625015, India
D. Kavitha
Assistant Professor, EEE department, Thiagarajar college of engineering, Madurai - 625015, India

Abstract


In this paper, a problem of allocation and sizing of multiple active power-line conditioners (aplcs) in power systems is handled with novel formulation. The utilized objective function comprises two main factors such as reduction of total harmonic distortion and the total cost of active power-line conditioners (aplcs). The formulated problem is solved by optimization technique Shuffle Frog Leap Algorithm (SHFLA) using MATLABTM. To evaluate the competence of the proposed formulation, the IEEE 18-bus distorted distribution test system is employed and investigated with various number of aplcs placement. These cases are based on the discrete and limited size for aplcs, requiring the optimization method to solve the constrained and discrete nonlinear problems. The comparison of results in this paper showed that the proposed SHFLA is the most effective result among others in determining optimum location and size of APLC in distribution systems.

Keywords


Active Power-Line Conditioner (APLC),Harmonics,Shuffle Frog Leap Algorithm(SHFLA), Optimal Allocation and Sizing of APLCs (OASA) problem.



DOI: https://doi.org/10.33686/prj.v12i1.189293