This paper presents the performance study of single axis tracking system compared static PV system. To increase the efficiency of PV System. We designed a simple and cost effective 170W sun tracking system for the experiment. The whole experimental setup has been implemented in SimulinkTM platform for the analysis of improved efficiency. The objective of this paper to optimize the solar energy receivers. In this paper, a Simulink model of the static PV system and Tracking PV system has been presented. In the fabrication of real sun tracker system we used a 24 VDC motor and a simple LDR based control circuit for the tracking purpose. The block diagram with detailed description and performance of the tracking system are presented.

Keywords

Dc-motor Model, Simulink Based Static Pv System, Solar Tracking System, Photovoltaic
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 247

PDF Views: 0




  • Improved Efficiency Study of Single Axis Tracking Model Compared to Static Photovoltaic System

Abstract Views: 247  |  PDF Views: 0

Authors

Neeraj Tiwari
Dayalbagh Educational Institute (Deemed University), Agra, India
Sanjeev Kumar
Hindustan College of Science and Technology, Mathura, India
Vikas Pratap Singh
Central Power Research Institute Bangalore, India

Abstract


This paper presents the performance study of single axis tracking system compared static PV system. To increase the efficiency of PV System. We designed a simple and cost effective 170W sun tracking system for the experiment. The whole experimental setup has been implemented in SimulinkTM platform for the analysis of improved efficiency. The objective of this paper to optimize the solar energy receivers. In this paper, a Simulink model of the static PV system and Tracking PV system has been presented. In the fabrication of real sun tracker system we used a 24 VDC motor and a simple LDR based control circuit for the tracking purpose. The block diagram with detailed description and performance of the tracking system are presented.

Keywords


Dc-motor Model, Simulink Based Static Pv System, Solar Tracking System, Photovoltaic



DOI: https://doi.org/10.33686/prj.v11i1.189387