Transients Instability Detection and Prevention Control Schemes


Affiliations
1 Power Systems Lab, Electrical Dept., IIT Madras, Chennai 600036, India
     

   Subscribe/Renew Journal


Effective real time monitoring and analysis of power system has become very important from the point of view of power system stability and security. Recent research in literature has identified that it is possible to determine the critical group of generators and hence predict the generators going out of synchronism. However, a clear mitigation scheme from a wide area perspective has not yet been identified. The main contribution of this paper deals with the post prediction of instability phase. After the identification of the critical generator or group of generators, effective actions such as load shedding should be initiated. The work targets in finding the optimal location where load is to be shed using the rotor angle algorithm and the Jacobian based distribution factor sensitivity

Keywords

Transient Instability Prediction, Wide Area Measurements, Synchrophasor, Rotor angle algorithm, Load shedding.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 202

PDF Views: 0




  • Transients Instability Detection and Prevention Control Schemes

Abstract Views: 202  |  PDF Views: 0

Authors

S. Parvathi
Power Systems Lab, Electrical Dept., IIT Madras, Chennai 600036, India
K. Shanti Swarup
Power Systems Lab, Electrical Dept., IIT Madras, Chennai 600036, India

Abstract


Effective real time monitoring and analysis of power system has become very important from the point of view of power system stability and security. Recent research in literature has identified that it is possible to determine the critical group of generators and hence predict the generators going out of synchronism. However, a clear mitigation scheme from a wide area perspective has not yet been identified. The main contribution of this paper deals with the post prediction of instability phase. After the identification of the critical generator or group of generators, effective actions such as load shedding should be initiated. The work targets in finding the optimal location where load is to be shed using the rotor angle algorithm and the Jacobian based distribution factor sensitivity

Keywords


Transient Instability Prediction, Wide Area Measurements, Synchrophasor, Rotor angle algorithm, Load shedding.



DOI: https://doi.org/10.33686/prj.v9i4.189534