A New Criterion for Optimal Dielectric Design of High Voltage Bushing Internal Shields in Large Power Transformer


Affiliations
1 High Voltage Engineering, R&D BHEL, Hyderabad – 502032, Telangana, India
2 Corporate R&D, ED, Hyderabad – 502032, Telangana, India
     

   Subscribe/Renew Journal


The High Voltage (HV) bushings are the most sensitive components of power transformers, they provide electrical insulation between the HV line and grounded tank, and also provide necessary mechanical support. The majority of transformer breakdowns are attributed to the HV bushings failures which are graded with conductive layers to improve their dielectric strength. The design of bushings is quite challenging with tradeoff between the axial and radial electric stresses. The bushing design is also governed by its mounting angle and transformer tank configuration to meet the internal and external flashover clearances and creepage requirements. At higher voltage levels, the configuration of HV bushing shield and grounded structural components have significant impact on dielectric withstand strength other than the clearances. Hence, it is very important to study the electrode configuration inside transformer tank for a particular bushing mounting arrangement before finalizing the bushing internal shield design. The 3D electrostatic field analysis of high voltage generator transformer was carried out for different bushing shield configurations to evaluate the electric stress distribution and the dielectric breakdown strength of the equipment was verified experimentally. The authors recommend to study the dielectric design of transformer in tandem with transformer configuration and a new evaluation criterion for optimal design of bushing internal shield is proposed.

Keywords

Bushing, Clearances, Dielectrics, Shields, Transformers.
User
Subscription Login to verify subscription
Notifications
Font Size

  • Ryan HM. High voltage engineering and testing; 2001. p. 744. https://doi.org/10.1049/PBPO032E
  • Kato K, Han X, Okubo H. Insulation optimization by electrode contour modification based on breakdown area/volume effects. IEEE Transactions on Dielectrics and Electrical Insulation. 2001; 8(2):162-167. https://doi.org/10.1109/94.919913
  • Kuffel E, Zaengl WS, Kuffel J. High voltage engineering fundamentals; 2000. p. 225.
  • Kulkarni SV, Khaparde SA. Transformer engineering design and practice. 8.3.5.
  • Kato K, Han X, Okubo H. Insulation optimization by electrode contour modification based on breakdown area/volume effects. IEEE Transactions on Dielectrics and Electrical Insulation. 2001; 8(2):162–7. https://doi.org/10.1109/94.919913

Abstract Views: 377

PDF Views: 1




  • A New Criterion for Optimal Dielectric Design of High Voltage Bushing Internal Shields in Large Power Transformer

Abstract Views: 377  |  PDF Views: 1

Authors

Pradeep Adusumilli
High Voltage Engineering, R&D BHEL, Hyderabad – 502032, Telangana, India
S. V. N. Jithin Sundar
Corporate R&D, ED, Hyderabad – 502032, Telangana, India

Abstract


The High Voltage (HV) bushings are the most sensitive components of power transformers, they provide electrical insulation between the HV line and grounded tank, and also provide necessary mechanical support. The majority of transformer breakdowns are attributed to the HV bushings failures which are graded with conductive layers to improve their dielectric strength. The design of bushings is quite challenging with tradeoff between the axial and radial electric stresses. The bushing design is also governed by its mounting angle and transformer tank configuration to meet the internal and external flashover clearances and creepage requirements. At higher voltage levels, the configuration of HV bushing shield and grounded structural components have significant impact on dielectric withstand strength other than the clearances. Hence, it is very important to study the electrode configuration inside transformer tank for a particular bushing mounting arrangement before finalizing the bushing internal shield design. The 3D electrostatic field analysis of high voltage generator transformer was carried out for different bushing shield configurations to evaluate the electric stress distribution and the dielectric breakdown strength of the equipment was verified experimentally. The authors recommend to study the dielectric design of transformer in tandem with transformer configuration and a new evaluation criterion for optimal design of bushing internal shield is proposed.