Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Objective Interpretation of SFRA, in the Light of CIGRE TB 812


Affiliations
1 HPL, Central Power Research Institute, Bengaluru – 560012, Karnataka, India
     

   Subscribe/Renew Journal


The SFRA (Sweep Frequency Response Analysis) technique has become quite popular as a condition monitoring technique for transformers. The SFRA technique holds a vast repertoire of data in terms of the electromagnetic behaviour of the transformer. Much research has happened in comprehending this data but no effort has succeeded in determining a universal objective criterion for the interpretation of SFRA data. CIGRE study committee A2.53 has recently released Technical Brochure 812 which has been the result of nearly half a decade of international efforts in arriving at an objective criterion for the interpretation of SFRA. This paper discusses the state of the art in objective interpretation of SFRA data with special reference to TB 812. The paper also presents a case study in HPL where SFRA was compared to a conventional method.

Keywords

Frequency Response, Power Transformers, Statistical Analysis.
User
Subscription Login to verify subscription
Notifications
Font Size

  • CIGRE Working Group A2.26. Mechanical-condition assessment of transformer windings using Frequency Response Analysis (FRA). Brochure 342; 2008.
  • Measurement of frequency response. IEC 60076-18; 2012.
  • IEEE Guide for the application and interpretation of Frequency Response Analysis for oil-immersed transformers. IEEE Standard C57.149-2012; 2013.
  • Frequency Response Analysis on winding deformation of power transformers. DL/T 911; 2016.
  • CIGRE Working Group A2.53. Advances in the interpretation of transformer Frequency Response Analysis (FRA). Brochure 812; 2020.
  • Nirgude PM, Ashokraju D, Rajkumar AD, Singh BP. Application of numerical evaluation techniques for interpreting frequency response measurements in power transformers. IET Science, Measurement and Technology. 2008; 2:275–85. https://doi.org/10.1049/iet-smt:20070072
  • Tahir M, Tenbohlen S. Novel calculation method for power transformer winding fault detection using Frequency Response Analysis. 5th International Colloquium “Transformer Research and Asset Management”; 2019.
  • Sreeram V, Reddy SS, Gurudev T, Maroti M, Rajkumar M. Investigation into the correlation of SFRA numerical indices and short circuit reactance measurements of transformers. Proceedings of 2nd Springer International Conference (Virtual Mode) On Machine Learning, Advances in Computing, Renewable Energy and Communication (MARC 2020), 2020 Dec 17–18, Krishna Engineering College, New Delhi; 2020.

Abstract Views: 142

PDF Views: 0




  • Objective Interpretation of SFRA, in the Light of CIGRE TB 812

Abstract Views: 142  |  PDF Views: 0

Authors

V. Sreeram
HPL, Central Power Research Institute, Bengaluru – 560012, Karnataka, India
T Gurudev
HPL, Central Power Research Institute, Bengaluru – 560012, Karnataka, India
M. Rajkumar
HPL, Central Power Research Institute, Bengaluru – 560012, Karnataka, India
M. Maroti
HPL, Central Power Research Institute, Bengaluru – 560012, Karnataka, India
S. Sudhakara Reddy
HPL, Central Power Research Institute, Bengaluru – 560012, Karnataka, India

Abstract


The SFRA (Sweep Frequency Response Analysis) technique has become quite popular as a condition monitoring technique for transformers. The SFRA technique holds a vast repertoire of data in terms of the electromagnetic behaviour of the transformer. Much research has happened in comprehending this data but no effort has succeeded in determining a universal objective criterion for the interpretation of SFRA data. CIGRE study committee A2.53 has recently released Technical Brochure 812 which has been the result of nearly half a decade of international efforts in arriving at an objective criterion for the interpretation of SFRA. This paper discusses the state of the art in objective interpretation of SFRA data with special reference to TB 812. The paper also presents a case study in HPL where SFRA was compared to a conventional method.

Keywords


Frequency Response, Power Transformers, Statistical Analysis.