A simple, accurate and precise spectroscopic method was developed for simultaneous estimation of Irbesartan and atorvastatin in synthetic mixture using Q absorption Ratio Method. In this spectroscopic method, 234.7 nm (as an isoabsorptive point) and 226 nm wavelengths (λmax of any of the two drugs) were selected for measurement of absorptivity. Both the drugs show linearity in a concentration range of 05-30 μg/ml at their respective λmax and at the isoabsorptive point. Accuracy, precision and recovery studies were done by QC samples covering lower, medium and high concentrations of the linearity range. The relative standard deviation for accuracy, precision studies were found to be within the acceptance range (<2%). The limit of determination was 0.365μg/ml and 0.0622μg/ml for Irbesartan and atorvastatin, respectively. The limit of quantification was 1.108μg/ml and 0.188μg/ml for Irbesartan and atorvastatin, respectively. Recovery of Irbesartan and atorvastatin were found to be 100.51% and 100.16% respectively confirming the accuracy of the proposed method. The proposed method is recommended for routine analysis since they are rapid, simple, accurate and also sensitive and specific by no heating and no organic solvent extraction.

Keywords

Irbesartan, Atorvastatin, Simultaneous Estimation, Q Absorption Ratio Method, Q Value Analysis Method.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 293

PDF Views: 0




  • Simultaneous Estimation of Irbesartan and Atorvastatin by Q Absorption Ratio Method in Their Synthetic Mixture

Abstract Views: 293  |  PDF Views: 0

Authors

Paras Virani
Gujarat Technological University, Gujarat, India
Rajanit Sojitra
Quality Assurance Department, Shree Dhanvantary Pharmacy College, Kim, Surat, India
Bhadresh Savaj
Quality Assurance Department, Shree Dhanvantary Pharmacy College, Kim, Surat, India
Hasumati Raj
Quality Assurance Department, Shree Dhanvantary Pharmacy College, Kim, Surat, India
Vineet Jain
Quality Assurance Department, Shree Dhanvantary Pharmacy College, Kim, Surat, India

Abstract


A simple, accurate and precise spectroscopic method was developed for simultaneous estimation of Irbesartan and atorvastatin in synthetic mixture using Q absorption Ratio Method. In this spectroscopic method, 234.7 nm (as an isoabsorptive point) and 226 nm wavelengths (λmax of any of the two drugs) were selected for measurement of absorptivity. Both the drugs show linearity in a concentration range of 05-30 μg/ml at their respective λmax and at the isoabsorptive point. Accuracy, precision and recovery studies were done by QC samples covering lower, medium and high concentrations of the linearity range. The relative standard deviation for accuracy, precision studies were found to be within the acceptance range (<2%). The limit of determination was 0.365μg/ml and 0.0622μg/ml for Irbesartan and atorvastatin, respectively. The limit of quantification was 1.108μg/ml and 0.188μg/ml for Irbesartan and atorvastatin, respectively. Recovery of Irbesartan and atorvastatin were found to be 100.51% and 100.16% respectively confirming the accuracy of the proposed method. The proposed method is recommended for routine analysis since they are rapid, simple, accurate and also sensitive and specific by no heating and no organic solvent extraction.

Keywords


Irbesartan, Atorvastatin, Simultaneous Estimation, Q Absorption Ratio Method, Q Value Analysis Method.