A simple, accurate and precise spectroscopic method was developed for simultaneous estimation of Amlodipine besylate and Simvastatin in synthetic mixture using Absorbance correction method. At 360.80 nm (λmax of Amlodipine besylate) Simvastatin has zero absorbance so Amlodipine besylate is directly estimate at 360.80 nm. At 237.60 nm (λmax of Simvastatin) both drugs have some absorbance so Simvastatin is estimate at 237.60 nm using absorbance correction method.The method was found to be linear (r2>0.999) in the range of 5-10 μμg/ml for Amlodipine besylate at 360.80 nm. The linear correlation was obtained (r2>0.999) in the range of 5-10 μg/ml for Simvastatin at 237.60 nm. The limit of determination was 0.17 μg/ml and 0.10 μg/ml for Amlodipine besylate and Simvastatin, respectively. The limit of quantification was 0. 54μg/ml and 0. 32μg/ml for Amlodipine besylate and Simvastatin, respectively. The accuracy of these method were evaluated by recovery studies and good recovery result were obtained greater than 99%. The method was successfully applied for simultaneous determination of Amlodipine besylate and Simvastatin in binary mixture.

Keywords

Amlodipine Besylate, Simvastatin, Absorption Correction Method.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 300

PDF Views: 0




  • Absorbance Correction Method for Simultaneous Estimation of Amlodipine Besylate and Simvastatin in Synthetic Mixture

Abstract Views: 300  |  PDF Views: 0

Authors

Vandana M. Patel
Department of Quality Assurance, Shree Dhanvantary College of Pharmacy, Kim, Surat, Gujarat, India
Hasumati A. Raj
Department of Quality Assurance, Shree Dhanvantary College of Pharmacy, Kim, Surat, Gujarat, India
Vineet C. Jain
Department of Quality Assurance, Shree Dhanvantary College of Pharmacy, Kim, Surat, Gujarat, India

Abstract


A simple, accurate and precise spectroscopic method was developed for simultaneous estimation of Amlodipine besylate and Simvastatin in synthetic mixture using Absorbance correction method. At 360.80 nm (λmax of Amlodipine besylate) Simvastatin has zero absorbance so Amlodipine besylate is directly estimate at 360.80 nm. At 237.60 nm (λmax of Simvastatin) both drugs have some absorbance so Simvastatin is estimate at 237.60 nm using absorbance correction method.The method was found to be linear (r2>0.999) in the range of 5-10 μμg/ml for Amlodipine besylate at 360.80 nm. The linear correlation was obtained (r2>0.999) in the range of 5-10 μg/ml for Simvastatin at 237.60 nm. The limit of determination was 0.17 μg/ml and 0.10 μg/ml for Amlodipine besylate and Simvastatin, respectively. The limit of quantification was 0. 54μg/ml and 0. 32μg/ml for Amlodipine besylate and Simvastatin, respectively. The accuracy of these method were evaluated by recovery studies and good recovery result were obtained greater than 99%. The method was successfully applied for simultaneous determination of Amlodipine besylate and Simvastatin in binary mixture.

Keywords


Amlodipine Besylate, Simvastatin, Absorption Correction Method.