Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Simultaneous UV Spectrophotometric Methods for Estimation of Ranitidine and Domperidonein Bulk and Tablet Dosage Form


Affiliations
1 Department of Pharmaceutics, Sahyadri College of Pharmacy, Methwade, Sangola-413307, Solapur, Maharashtra, India
2 Department of Quality Assurance, Shri D.D. Vispute College of Pharmacy and Research Centre, Devad-Vichumbe, New Panvel, Raigad-410206, Maharashtra, India
     

   Subscribe/Renew Journal


Two simple, precise, economical, fast and reliable UV methods have been developed for the simultaneous estimation of Ranitidine and Domperidone in bulk and pharmaceutical dosage form. Method A is Absorbance maxima method, which is based on measurement of absorption at maximum wavelength of 314 nm and 286 nm for Ranitidine and Domperidone respectively. Method B is area under curve (AUC), in the wavelength range of 269-340nm for Ranitidine and 262-307nm for Domperidone. Linearity for detector response was observed in the concentration range of 5-25μg/ml for Ranitidine and 5-25 μg/ml for Domperidone. The accuracy of the methods was assessed by recovery studies and was found to be 99.18% and 100.21% for Ranitidine and 100.19% and 101.57% Domperidone by using method A and B respectively. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were validated statistically as per ICH Q2 R1guideline and were found to be satisfactory. The proposed methods were successfully applied for the determination of for Ranitidine and Domperidone in commercial pharmaceutical dosage form.

Keywords

Ranitidine, Domperidone, Simultaneous Estimation, Precision, Absorbance Maxima Method, Area under Curve.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 238

PDF Views: 1




  • Simultaneous UV Spectrophotometric Methods for Estimation of Ranitidine and Domperidonein Bulk and Tablet Dosage Form

Abstract Views: 238  |  PDF Views: 1

Authors

Audumbar Mali
Department of Pharmaceutics, Sahyadri College of Pharmacy, Methwade, Sangola-413307, Solapur, Maharashtra, India
Sujata Kolekar
Department of Quality Assurance, Shri D.D. Vispute College of Pharmacy and Research Centre, Devad-Vichumbe, New Panvel, Raigad-410206, Maharashtra, India
Jija Franklin
Department of Quality Assurance, Shri D.D. Vispute College of Pharmacy and Research Centre, Devad-Vichumbe, New Panvel, Raigad-410206, Maharashtra, India
Ritesh Bathe
Department of Pharmaceutics, Sahyadri College of Pharmacy, Methwade, Sangola-413307, Solapur, Maharashtra, India

Abstract


Two simple, precise, economical, fast and reliable UV methods have been developed for the simultaneous estimation of Ranitidine and Domperidone in bulk and pharmaceutical dosage form. Method A is Absorbance maxima method, which is based on measurement of absorption at maximum wavelength of 314 nm and 286 nm for Ranitidine and Domperidone respectively. Method B is area under curve (AUC), in the wavelength range of 269-340nm for Ranitidine and 262-307nm for Domperidone. Linearity for detector response was observed in the concentration range of 5-25μg/ml for Ranitidine and 5-25 μg/ml for Domperidone. The accuracy of the methods was assessed by recovery studies and was found to be 99.18% and 100.21% for Ranitidine and 100.19% and 101.57% Domperidone by using method A and B respectively. The developed method was validated with respect to linearity, accuracy (recovery), precision and specificity. The results were validated statistically as per ICH Q2 R1guideline and were found to be satisfactory. The proposed methods were successfully applied for the determination of for Ranitidine and Domperidone in commercial pharmaceutical dosage form.

Keywords


Ranitidine, Domperidone, Simultaneous Estimation, Precision, Absorbance Maxima Method, Area under Curve.