Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Absorption Correction Method for Simultaneous Estimation of Nifedipine and Metoprolol Succinate in Their Synthetic Mixture Using From Spectrophotometry


Affiliations
1 Department of Quality Assurance, Shree Dhanvantry Pharmacy College, Kim, Surat, India
     

   Subscribe/Renew Journal


A new simple, economical, precise and accurate method are described for the simultaneous determination of Nifedipine (NIF) and Metoprolol Succinate (MET) in combined tablet dosage form. The proposed method was applied for the determination of Nifedipine and Metoprolol Succinate in synthetic mixture, for determination of sampling wavelength, 10μg/ml of each of NIF and MET were scanned in 200-400 nm range and sampling wavelengths were 313nm for NIF and 275.40nm for MET are selected for development and validation of absorption correction method. For this method linearity observed in the range of 5-25μg/ml for NIF and 25-125μg/ml for MET, and in their pharmaceutical formulation with mean percentage recoveries 100.68 and 100.33, respectively. The method was validated according to ICH guidelines and can be applied for routine quality control testing.

Keywords

Spectroscopic Method, Absorption Correctedmethod, Nifedipine And Metoprolol Succinate.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 272

PDF Views: 0




  • Absorption Correction Method for Simultaneous Estimation of Nifedipine and Metoprolol Succinate in Their Synthetic Mixture Using From Spectrophotometry

Abstract Views: 272  |  PDF Views: 0

Authors

Sojitra Rajanit
Department of Quality Assurance, Shree Dhanvantry Pharmacy College, Kim, Surat, India
Virani Paras
Department of Quality Assurance, Shree Dhanvantry Pharmacy College, Kim, Surat, India
Hashumati Raj
Department of Quality Assurance, Shree Dhanvantry Pharmacy College, Kim, Surat, India

Abstract


A new simple, economical, precise and accurate method are described for the simultaneous determination of Nifedipine (NIF) and Metoprolol Succinate (MET) in combined tablet dosage form. The proposed method was applied for the determination of Nifedipine and Metoprolol Succinate in synthetic mixture, for determination of sampling wavelength, 10μg/ml of each of NIF and MET were scanned in 200-400 nm range and sampling wavelengths were 313nm for NIF and 275.40nm for MET are selected for development and validation of absorption correction method. For this method linearity observed in the range of 5-25μg/ml for NIF and 25-125μg/ml for MET, and in their pharmaceutical formulation with mean percentage recoveries 100.68 and 100.33, respectively. The method was validated according to ICH guidelines and can be applied for routine quality control testing.

Keywords


Spectroscopic Method, Absorption Correctedmethod, Nifedipine And Metoprolol Succinate.