Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Analysis of Pesticide Residues in Ground and Surface Water of Bijapur District, Karnataka


Affiliations
1 Singhania University, Rajasthan, India
2 S.B. Arts and K.C.P. Science College, Bijapur, India
     

   Subscribe/Renew Journal


Water samples were analysed for pesticide residues employing multi residue analysis by gas chromatography mass spectrometric method (GC-MS) method and GC-MS on the selected ion mode. The column used was SPB-608 and helium was used as the carrier gas. The HP gas chromatograph equipped with nitrogen phosphorous detector with mega bore column of polysiloxane was used. Among the organochlorines, HCH and DDT were not detected in almost all samples. All the water samples showed the presence of residues with one or other group of residues. Residues of the pesticides exceeded the permissible values in some samples. The aim of this study was to establish a systematic analytical method for the rapid and sensitive probe in monitoring of pesticide residues in water samples of Bijapur ground and surface water.

Keywords

HPLC, Pesticide Residues, Bijapur District.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 256

PDF Views: 0




  • Analysis of Pesticide Residues in Ground and Surface Water of Bijapur District, Karnataka

Abstract Views: 256  |  PDF Views: 0

Authors

U. S. Pujeri
Singhania University, Rajasthan, India
S. C. Hiremath
S.B. Arts and K.C.P. Science College, Bijapur, India
A. S. Pujari
S.B. Arts and K.C.P. Science College, Bijapur, India
K. G. Pujari
S.B. Arts and K.C.P. Science College, Bijapur, India
M. I. Kumbar
S.B. Arts and K.C.P. Science College, Bijapur, India
M. S. Yadawe
S.B. Arts and K.C.P. Science College, Bijapur, India

Abstract


Water samples were analysed for pesticide residues employing multi residue analysis by gas chromatography mass spectrometric method (GC-MS) method and GC-MS on the selected ion mode. The column used was SPB-608 and helium was used as the carrier gas. The HP gas chromatograph equipped with nitrogen phosphorous detector with mega bore column of polysiloxane was used. Among the organochlorines, HCH and DDT were not detected in almost all samples. All the water samples showed the presence of residues with one or other group of residues. Residues of the pesticides exceeded the permissible values in some samples. The aim of this study was to establish a systematic analytical method for the rapid and sensitive probe in monitoring of pesticide residues in water samples of Bijapur ground and surface water.

Keywords


HPLC, Pesticide Residues, Bijapur District.