Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Optimization and Validation for Simultaneous Estimation of Citicoline and Piracetam in Bulk and Tablet Formulations Using RP-HPLC Method:Analytical Quality by Design Approach


Affiliations
1 KIET School of Pharmacy, Ghaziabad 201206, Uttar Pradesh, India
2 H.R. Institute of Pharmacy, Ghaziabad-201206, Uttar Pradesh, India
3 Glocal School of Pharmacy, Glocal University, Saharanpur-247121, Uttar Pradesh, India
     

   Subscribe/Renew Journal


The present work describes a reversed phase high performance liquid chromatographic method for simultaneous estimation of Citicoline (CIT) and Piracetam (PIR) in bulk as well as tablet dosage forms. The estimation was carried out on a C18 column using mobile mixture of acetonitrile and 10 mM disodium hydrogen phosphate buffer in the ratio of 10:90 (v/v) as a mobile phase. All analytes were detected by measuring the absorbance at 205 nm with flow rate of 1.0 ml/min. The total run time of the study was 16 min. for complete separation of both drugs. The elution was achieved at the retention times of 3.79 and 13.08 min for Citicoline, and Piracetam, respectively. The method was validated for accuracy, precision, linearity, specificity and sensitivity as per ICH norms. The calibration curves were found linear over the concentration ranges of 4-40μg/mL for Citicoline and 5-50μg/mL for Piracetam. From the validation study it was found that the method is specific, rapid, accurate and precise.

Keywords

Citicoline, Piracetam, RP-HPLC, Box Behnken Design, Validation.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 145

PDF Views: 1




  • Optimization and Validation for Simultaneous Estimation of Citicoline and Piracetam in Bulk and Tablet Formulations Using RP-HPLC Method:Analytical Quality by Design Approach

Abstract Views: 145  |  PDF Views: 1

Authors

Ashu Mittal
KIET School of Pharmacy, Ghaziabad 201206, Uttar Pradesh, India
Shikha Parmar
H.R. Institute of Pharmacy, Ghaziabad-201206, Uttar Pradesh, India
Sadaf Jamal Gilani
Glocal School of Pharmacy, Glocal University, Saharanpur-247121, Uttar Pradesh, India
Syed Sarim Imam
Glocal School of Pharmacy, Glocal University, Saharanpur-247121, Uttar Pradesh, India
Mohamad Taleuzzaman
Glocal School of Pharmacy, Glocal University, Saharanpur-247121, Uttar Pradesh, India

Abstract


The present work describes a reversed phase high performance liquid chromatographic method for simultaneous estimation of Citicoline (CIT) and Piracetam (PIR) in bulk as well as tablet dosage forms. The estimation was carried out on a C18 column using mobile mixture of acetonitrile and 10 mM disodium hydrogen phosphate buffer in the ratio of 10:90 (v/v) as a mobile phase. All analytes were detected by measuring the absorbance at 205 nm with flow rate of 1.0 ml/min. The total run time of the study was 16 min. for complete separation of both drugs. The elution was achieved at the retention times of 3.79 and 13.08 min for Citicoline, and Piracetam, respectively. The method was validated for accuracy, precision, linearity, specificity and sensitivity as per ICH norms. The calibration curves were found linear over the concentration ranges of 4-40μg/mL for Citicoline and 5-50μg/mL for Piracetam. From the validation study it was found that the method is specific, rapid, accurate and precise.

Keywords


Citicoline, Piracetam, RP-HPLC, Box Behnken Design, Validation.