Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Development and Validation of Reverse Phase High Performance Liquid Chromatography Method for the Estimation of Pravastatin Sodium in Tablet Dosage Form


Affiliations
1 APMC College of Pharmaceutical Education and Research, College Campus, Motipura, Himatnagar-383001, Gujarat, India
2 L.M. College of Pharmacy, Ahmedabad-380009, Gujarat, India
     

   Subscribe/Renew Journal


Pravastatin sodium is a HMG Co A reductase inhibitor, used as a lipid lowering agent. A simple, precise, rapid, accurate and cost effective high performance liquid chromatography (HPLC) method was successfully developed and validated for estimation of pravastatin sodium in tablet dosage form. Chromatographic separation was achieved on a Luna C18 column (250 mm×4.6 mm) utilizing mobile phase methanol and aqueous solution of o-phosphoric acid (0.6% v/v) at a flow rate of 1.0 ml/min with UV detection at 239 nm. A linear response was observed in the range of 14-26 μg/ml with correlation co-efficient of 0.9997. The mean percent recoveries of pravastatin sodium in tablet formulations were found to be in the range of 98.9-100.2%. The intra day and inter day precision was found to be within limits. The proposed method has adequate specificity, sensitivity and reproducibility for quality control assay of pravastatin sodium in tablet dosage form without any interference from excipients.

Keywords

Pravastatin Sodium, RP-HPLC Method, HMG Co A Reductase Inhibitor.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 179

PDF Views: 0




  • Development and Validation of Reverse Phase High Performance Liquid Chromatography Method for the Estimation of Pravastatin Sodium in Tablet Dosage Form

Abstract Views: 179  |  PDF Views: 0

Authors

D. B. Doshi
APMC College of Pharmaceutical Education and Research, College Campus, Motipura, Himatnagar-383001, Gujarat, India
P. A. Bhatt
L.M. College of Pharmacy, Ahmedabad-380009, Gujarat, India

Abstract


Pravastatin sodium is a HMG Co A reductase inhibitor, used as a lipid lowering agent. A simple, precise, rapid, accurate and cost effective high performance liquid chromatography (HPLC) method was successfully developed and validated for estimation of pravastatin sodium in tablet dosage form. Chromatographic separation was achieved on a Luna C18 column (250 mm×4.6 mm) utilizing mobile phase methanol and aqueous solution of o-phosphoric acid (0.6% v/v) at a flow rate of 1.0 ml/min with UV detection at 239 nm. A linear response was observed in the range of 14-26 μg/ml with correlation co-efficient of 0.9997. The mean percent recoveries of pravastatin sodium in tablet formulations were found to be in the range of 98.9-100.2%. The intra day and inter day precision was found to be within limits. The proposed method has adequate specificity, sensitivity and reproducibility for quality control assay of pravastatin sodium in tablet dosage form without any interference from excipients.

Keywords


Pravastatin Sodium, RP-HPLC Method, HMG Co A Reductase Inhibitor.