Simultaneous Spectrophotometric Estimation of Tamsulosin in Pharmaceutical Dosage Form


Affiliations
1 Dr. D. Y. Patil Institute of Pharmaceutical Sciences and Research, Pimpri, Pune, Maharashtra, India
     

   Subscribe/Renew Journal


Three simple, precise and economical UV methods have been developed for the estimation of Tamsulosin in pharmaceutical dosage form. Tamsulosin has the absorbance maxima at 281.0 nm (Method A), and in the first order derivative spectra, showed sharp peak at 234.5 nm (Method B). Method C applied was area under curve (AUC), in the wavelength range of 286.0-276.0 nm. Linearity for detector response was observed in the concentration range of 5-25 μg/ml for all three methods. The proposed methods were successfully applied for the simultaneous determination of Tamsulosin in commercial pharmaceutical preparation. The results of the capsule analysis were validated statistically and by recovery studies. It was found to be satisfactory.

Keywords

Tamsulosin, Absorbance Maxima, Derivative Spectroscopy, Area Under Curve.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 219

PDF Views: 0




  • Simultaneous Spectrophotometric Estimation of Tamsulosin in Pharmaceutical Dosage Form

Abstract Views: 219  |  PDF Views: 0

Authors

R. K. Nanda
Dr. D. Y. Patil Institute of Pharmaceutical Sciences and Research, Pimpri, Pune, Maharashtra, India
J. Gaikwad
Dr. D. Y. Patil Institute of Pharmaceutical Sciences and Research, Pimpri, Pune, Maharashtra, India
A. Prakash
Dr. D. Y. Patil Institute of Pharmaceutical Sciences and Research, Pimpri, Pune, Maharashtra, India

Abstract


Three simple, precise and economical UV methods have been developed for the estimation of Tamsulosin in pharmaceutical dosage form. Tamsulosin has the absorbance maxima at 281.0 nm (Method A), and in the first order derivative spectra, showed sharp peak at 234.5 nm (Method B). Method C applied was area under curve (AUC), in the wavelength range of 286.0-276.0 nm. Linearity for detector response was observed in the concentration range of 5-25 μg/ml for all three methods. The proposed methods were successfully applied for the simultaneous determination of Tamsulosin in commercial pharmaceutical preparation. The results of the capsule analysis were validated statistically and by recovery studies. It was found to be satisfactory.

Keywords


Tamsulosin, Absorbance Maxima, Derivative Spectroscopy, Area Under Curve.