Spectrophotometric Estimation of Carbocisteine in Bulk and Pharmaceutical Dosage form by first Order Derivative and Area under Curve Methods


Affiliations
1 Central Research Laboratory, D.G. Ruparel College, Matunga, Mumbai 400016
     

   Subscribe/Renew Journal


A simple and precise first order derivative and area under curve [AUC] UV- spectrophotometric methods have been developed and validated for the estimation of carbocisteine in bulk and its tablet formulation. The standard and sample solutions of carbocisteine were prepared in 0.1 N HCl. Carbocisteine was estimated at 198.4 nm for the first order derivative UV-spectrophotometric method (A), while in area under curve (AUC) method (B) the zero order spectrum of carbocisteine was measured in between 197.4 nm to 210.2 nm. Beer's law was obeyed in the concentration range of 10 to 140 µg / ml with coefficient of correlation value 0.9999 for first order derivative method. Similarly in AUC method, Beer's law was obeyed in the concentration range of 10 to 140 μg / ml with coefficient of correlation value 0.9999. These methods were tested and validated for various parameters according to ICH guidelines. The precision expressed as relative standard deviation, which was within the range of 0.02560 % to 0.13375 % for the above two methods. The proposed methods were successfully applied for the determination of carbocisteine in pharmaceutical formulation. Results of the analysis were validated statistically and were found to be satisfactory. The proposed methods are simple, easy to apply, low-cost and require relatively inexpensive instruments.

Keywords

Carbocisteine, Derivative Spectroscopy, Area under Curve Method
Subscription Login to verify subscription
User
Notifications
Font Size


  • British Pharmacopoeia, Her Majesty’s Stationary Office, London. Volume I, II, and III, 1983, 2009.
  • European Pharmacopoeia 5.0. Volume-2; 2005.
  • Rele RV, Patil SP. Reversed phase high pressure liquid chromatography technique for determination of carbocisteine from pharmaceutical formulation. J.Chem.Parm.Res. 2(4); 2010: 24-30.
  • Archana Nadimintri, Ashwini Gunda, Karnaker Reddy Tupally, Abbaraju Prasanna Lakshmi, Kedarnath Jakka, Aravind Sai Nagubandi. Simultaneous estimation of amoxillcine trihydrate and carbocisteine drug present in formulation by RP-HPLC method and its validation. Journal of pharmacy research. 5(4); 2012: 1889-1895.
  • Ravindhar Burugu, G.Venkateshwarlu. A stability indicating ultra performance liquid chromatography (UPLC) method for the determination of assay of carbocisteine in various formulation products. International journal of pharmacy and pharmaceutical sciences. 4(4); 2012: 653-656.
  • Megoulas NC, Koupparis MA. Ion-chromatographic determination of carbocisteine in pharmaceuticals based on nonsuppressed conductometric detection. J.chromatography A. 1026 (1-2); 2004: 167-74.
  • ICH, Q2A Text on Validation of Analytical Procedures; 1994.
  • ICH, Q2B Validation of Analytical Methodology; 1996.
  • ICH, Q2 (R1) Validation of Analytical Procedures: text and methodology; 2005.

Abstract Views: 319

PDF Views: 2




  • Spectrophotometric Estimation of Carbocisteine in Bulk and Pharmaceutical Dosage form by first Order Derivative and Area under Curve Methods

Abstract Views: 319  |  PDF Views: 2

Authors

V Rele Rajan
Central Research Laboratory, D.G. Ruparel College, Matunga, Mumbai 400016
S Patil Sachin
Central Research Laboratory, D.G. Ruparel College, Matunga, Mumbai 400016

Abstract


A simple and precise first order derivative and area under curve [AUC] UV- spectrophotometric methods have been developed and validated for the estimation of carbocisteine in bulk and its tablet formulation. The standard and sample solutions of carbocisteine were prepared in 0.1 N HCl. Carbocisteine was estimated at 198.4 nm for the first order derivative UV-spectrophotometric method (A), while in area under curve (AUC) method (B) the zero order spectrum of carbocisteine was measured in between 197.4 nm to 210.2 nm. Beer's law was obeyed in the concentration range of 10 to 140 µg / ml with coefficient of correlation value 0.9999 for first order derivative method. Similarly in AUC method, Beer's law was obeyed in the concentration range of 10 to 140 μg / ml with coefficient of correlation value 0.9999. These methods were tested and validated for various parameters according to ICH guidelines. The precision expressed as relative standard deviation, which was within the range of 0.02560 % to 0.13375 % for the above two methods. The proposed methods were successfully applied for the determination of carbocisteine in pharmaceutical formulation. Results of the analysis were validated statistically and were found to be satisfactory. The proposed methods are simple, easy to apply, low-cost and require relatively inexpensive instruments.

Keywords


Carbocisteine, Derivative Spectroscopy, Area under Curve Method

References