Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

RP-HPLC Method for the Simultaneous Estimation of Moxifloxacin Hydrochloride and Cefixime Trihydrate in Synthetic Mixture


Affiliations
1 Department of Pharmaceutical Quality Assurance, Parul Institute of Pharmacy and Research, Limda, Ta. Waghodia, Dist. Vadodara -391760, Gujarat
     

   Subscribe/Renew Journal


A simple, selective, accurate Reverse Phase High Performance Liquid Chromatographic method was developed and validated for the simultaneous estimation of Moxifloxacin hydrochloride and Cefixime trihydrate in their synthetic mixture. Chromatographic separation achieved isocratically on a thermoscientific BDS Hypersil C18 (250mm X 4.6 mm i.d., 5 μm particle size) column utilizing a mobile phase of acetonitrile: tetrabutyl ammonium hydrogen sulphate (TBAHS) + tetrabutyl ammonium bromide (TBAB) buffer pH 3 (20:80 v/v) and adjusting pH 3 with orthophosphoric acid at a flow rate of 1.5ml/min with UV detection at 280.8nm. The retention time for Moxifloxacin hydrochloride and Cefixime trihydrate was found to be 3.078 and 5.263 min respectively. Linearity was obtained in the concentration range of 10-60μg/ml of Moxifloxacin hydrochloride and 10-60μg/ml of Cefixime trihydrate with a correlation coefficient of 0.999 and 0.999 respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantitation. This study aimed at developing and validating an HPLC method being simple, accurate, robust and selective and the proposed method can be used for the estimation of these drugs in combined synthetic mixture.

Keywords

Simultaneous Estimation, RP-HPLC, Moxifloxacin Hydrochloride, Cefixime Trihydrate
Subscription Login to verify subscription
User
Notifications
Font Size



  • RP-HPLC Method for the Simultaneous Estimation of Moxifloxacin Hydrochloride and Cefixime Trihydrate in Synthetic Mixture

Abstract Views: 951  |  PDF Views: 2

Authors

Hemina P. Patel
Department of Pharmaceutical Quality Assurance, Parul Institute of Pharmacy and Research, Limda, Ta. Waghodia, Dist. Vadodara -391760, Gujarat
Jawed Akhtar
Department of Pharmaceutical Quality Assurance, Parul Institute of Pharmacy and Research, Limda, Ta. Waghodia, Dist. Vadodara -391760, Gujarat

Abstract


A simple, selective, accurate Reverse Phase High Performance Liquid Chromatographic method was developed and validated for the simultaneous estimation of Moxifloxacin hydrochloride and Cefixime trihydrate in their synthetic mixture. Chromatographic separation achieved isocratically on a thermoscientific BDS Hypersil C18 (250mm X 4.6 mm i.d., 5 μm particle size) column utilizing a mobile phase of acetonitrile: tetrabutyl ammonium hydrogen sulphate (TBAHS) + tetrabutyl ammonium bromide (TBAB) buffer pH 3 (20:80 v/v) and adjusting pH 3 with orthophosphoric acid at a flow rate of 1.5ml/min with UV detection at 280.8nm. The retention time for Moxifloxacin hydrochloride and Cefixime trihydrate was found to be 3.078 and 5.263 min respectively. Linearity was obtained in the concentration range of 10-60μg/ml of Moxifloxacin hydrochloride and 10-60μg/ml of Cefixime trihydrate with a correlation coefficient of 0.999 and 0.999 respectively. The developed method was validated in terms of accuracy, precision, linearity, limit of detection, limit of quantitation. This study aimed at developing and validating an HPLC method being simple, accurate, robust and selective and the proposed method can be used for the estimation of these drugs in combined synthetic mixture.

Keywords


Simultaneous Estimation, RP-HPLC, Moxifloxacin Hydrochloride, Cefixime Trihydrate

References