Performance Analysis of Denoising Methods on Brain CT Images
Subscribe/Renew Journal
This paper presents a comparative assessment of various denoising methods on brain CT images. The paper quantitatively compares total of four denoising methods namely wiener filter, median filter, anisotropic diffusion and total variation (TV). The focus of this work is to compare these methods not only for the suppression of noise but also for the preservation of fine details and edges on brain CT images. The experimental results show that the wiener filter shows the best performance in terms of perceptual quality, noise suppression and edge preservation. It yields the higher values of SNR, PSNR, UQI and EKI as compared to other denoising methods. This is an evidence of the maximum noise suppression with significant edges and fine details preservation.Total variation method induces some staircase effect and loss of fine details. Wavelet based method yields better denoising particularly in homogenous regions but does not gives better results in edgy regions and anisotropic diffusion method shows blurring effect and thus edges and fine details are lost.
Keywords
Computed Tomography (CT), Total Variation (TV), Anisotropic Diffusion (AD).
User
Subscription
Login to verify subscription
Font Size
Information
Abstract Views: 234
PDF Views: 2