Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Performance Analysis of Multi Level Shunt Active Filter Based on SDM


Affiliations
1 Department of Electrical and Electronics Engineering, A.C. College of Engineering and Technology, Karaikudi, India
2 KEC International LTD, UNNAO, Uttar Pradesh, India
3 Department of Electrical and Electronics Engineering, AMS Engineering College, Namkkal, India
4 Department of Applied Science, Paavai Engineering College, Pachal, Namakkal, India
     

   Subscribe/Renew Journal


A new shunt active filter is proposed here to reduce the harmonic contents in source voltage and source currents of a harmonic polluted three phase system supplying a non – linear load. The shunt active filter is designed with multi level cascaded H-bridge inverter. To generate the required compensation currents multi carrier PWM Currents are extracted from the load power using Synchronous Detection Method. Simulation of the active filter with proposed current control and dc bus control is presented. The harmonic filter reduces the harmonic contents in source currents as well as the source voltage multilevel shunt active filter does not require an interfacing transformer to connect it with the high power system. It reduces the filter current ripples and improve source power factor.

Keywords

Point of Common Coupling (PCC), Synchronous Detection Method (SDM), Multi-Carrier Pulse Width Modulation, Total harmonic Distortion (THD).
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 181

PDF Views: 3




  • Performance Analysis of Multi Level Shunt Active Filter Based on SDM

Abstract Views: 181  |  PDF Views: 3

Authors

P. Ganesan
Department of Electrical and Electronics Engineering, A.C. College of Engineering and Technology, Karaikudi, India
Sreejith B. Kurup
KEC International LTD, UNNAO, Uttar Pradesh, India
D. Mohan
Department of Electrical and Electronics Engineering, AMS Engineering College, Namkkal, India
D. Kalyani
Department of Applied Science, Paavai Engineering College, Pachal, Namakkal, India

Abstract


A new shunt active filter is proposed here to reduce the harmonic contents in source voltage and source currents of a harmonic polluted three phase system supplying a non – linear load. The shunt active filter is designed with multi level cascaded H-bridge inverter. To generate the required compensation currents multi carrier PWM Currents are extracted from the load power using Synchronous Detection Method. Simulation of the active filter with proposed current control and dc bus control is presented. The harmonic filter reduces the harmonic contents in source currents as well as the source voltage multilevel shunt active filter does not require an interfacing transformer to connect it with the high power system. It reduces the filter current ripples and improve source power factor.

Keywords


Point of Common Coupling (PCC), Synchronous Detection Method (SDM), Multi-Carrier Pulse Width Modulation, Total harmonic Distortion (THD).