Preoperative templating in Total Hip Replacement (THR) is a method to estimate the optimal size and position of the implant. Today, observational (manual) size recognition techniques are still used to find a suitable implant for the patient. Therefore, a digital and automated technique should be developed so that the implant size recognition process can be effectively implemented. For this purpose, we have introduced the new technique for acetabular implant size recognition in THR preoperative planning based on the diameter of acetabulum size. This technique enables the surgeon to recognise a digital acetabular implant size automatically. Ten randomly selected X-rays of unidentified patients were used to test the accuracy and utility of an automated implant size recognition technique. Based on the testing result, the new technique yielded very close results to those obtained by the observational method in nine studies (90%).

Keywords

Total Hip Replacement, Implant, Templating, Digital, Preoperative, X-Ray.
User
Notifications
Font Size

Abstract Views: 332

PDF Views: 150




  • An Automated Size Recognition Technique for Acetabular Implant in Total Hip Replacement

Abstract Views: 332  |  PDF Views: 150

Authors

A. Shapi'i
Industrial Computing Research Group, Universiti Kebangsaan Malaysia, Malaysia
R. Sulaiman
School of Information Technology, Universiti Kebangsaan Malaysia, Malaysia
M. K. Hasan
Information Technology Center, Universiti Kebangsaan Malaysia, Malaysia
A. Y. M. Kassim
Department of Orthopaedic and Traumalogy, Medical Center of Universiti Kebangsaan, Malaysia

Abstract


Preoperative templating in Total Hip Replacement (THR) is a method to estimate the optimal size and position of the implant. Today, observational (manual) size recognition techniques are still used to find a suitable implant for the patient. Therefore, a digital and automated technique should be developed so that the implant size recognition process can be effectively implemented. For this purpose, we have introduced the new technique for acetabular implant size recognition in THR preoperative planning based on the diameter of acetabulum size. This technique enables the surgeon to recognise a digital acetabular implant size automatically. Ten randomly selected X-rays of unidentified patients were used to test the accuracy and utility of an automated implant size recognition technique. Based on the testing result, the new technique yielded very close results to those obtained by the observational method in nine studies (90%).

Keywords


Total Hip Replacement, Implant, Templating, Digital, Preoperative, X-Ray.