Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Open Loop and Closed Loop Control on Indirect Field Oriented Control for Induction Motor with Fault Analysis


Affiliations
1 Department of EEE, Kongu Engineering College, Erode - 638052, Tamilnadu, India
2 Department of EEE, M. Kumarasamy College of Engineering, Karur - 639 113, Tamilnadu, India
     

   Subscribe/Renew Journal


This paper gives information of three phase induction motor operates indirect field oriented control which rotor flux DQ model is presented. In this paper various faults are analyzed such as voltage, current, speed and torque, stator flux for both open loop and closed loop control and experimentally explained. To develop the model, faults are first identified, and faults are injected then, a simulation model of the setup is developed. Faults are injected into the model in sequential levels and the system performance is analyzed after each and every fault. Then experimentally phase to phase fault and single phase faults are also studied. Here IFOC with rotor flux DQ model was simulated using MATLAB/ SIMULINK software and verified experimentally. Also the waveforms of voltage, current, speed, torque, Q axis and D axis stator flux are obtained. The above faults are analyzed and rectified which results in the increase of system performance.

Keywords

Fault Impact Assessment, Induction Motor Drive, Rotor Flux DQ Axis Model,openloop and Closedloop IFOC.
User
Subscription Login to verify subscription
Notifications
Font Size

Abstract Views: 324

PDF Views: 2




  • Open Loop and Closed Loop Control on Indirect Field Oriented Control for Induction Motor with Fault Analysis

Abstract Views: 324  |  PDF Views: 2

Authors

P. Santhoshini
Department of EEE, Kongu Engineering College, Erode - 638052, Tamilnadu, India
R. Senthil kumar
Department of EEE, M. Kumarasamy College of Engineering, Karur - 639 113, Tamilnadu, India

Abstract


This paper gives information of three phase induction motor operates indirect field oriented control which rotor flux DQ model is presented. In this paper various faults are analyzed such as voltage, current, speed and torque, stator flux for both open loop and closed loop control and experimentally explained. To develop the model, faults are first identified, and faults are injected then, a simulation model of the setup is developed. Faults are injected into the model in sequential levels and the system performance is analyzed after each and every fault. Then experimentally phase to phase fault and single phase faults are also studied. Here IFOC with rotor flux DQ model was simulated using MATLAB/ SIMULINK software and verified experimentally. Also the waveforms of voltage, current, speed, torque, Q axis and D axis stator flux are obtained. The above faults are analyzed and rectified which results in the increase of system performance.

Keywords


Fault Impact Assessment, Induction Motor Drive, Rotor Flux DQ Axis Model,openloop and Closedloop IFOC.