Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Performance Evaluation of Multilevel Shunt Active Power Filter using Fuzzy PI Control for Aircraft Power Utility


Affiliations
1 Department of Electrical and Electronics Engineering, Sona College of Technology, India
2 Department of Department of Electrical and Electronics Engineering, AVS Engineering College, India
     

   Subscribe/Renew Journal


The implementation of electric power in aircraft system increases the use of different kinds of power electronic converters such as AC/DC rectifiers, DC/AC inverters and DC/DC choppers in the system. The incursion of numerous power electronic devices leads to complex network and also causes power quality and stability issues. The current harmonics may cause unbalance in the aircraft electric power system and severe voltage distortion. Thus, the active filters can compensate the harmonics, improves the power factor and work as a reactive power compensator, thus in turn afford power quality enhancement of the system. This work proposes the use of a five level cascaded H-bridge VSI with an improved current control and a suitably developed modulation strategy to reduce harmonics in air craft system.

Keywords

Power Quality, Active Power Filter, Fuzzy PI controller, Harmonics Compensation.
Subscription Login to verify subscription
User
Notifications
Font Size

Abstract Views: 188

PDF Views: 0




  • Performance Evaluation of Multilevel Shunt Active Power Filter using Fuzzy PI Control for Aircraft Power Utility

Abstract Views: 188  |  PDF Views: 0

Authors

K. S. Yamuna
Department of Electrical and Electronics Engineering, Sona College of Technology, India
R. Shivakumar
Department of Electrical and Electronics Engineering, Sona College of Technology, India
B. Sangeetha
Department of Department of Electrical and Electronics Engineering, AVS Engineering College, India

Abstract


The implementation of electric power in aircraft system increases the use of different kinds of power electronic converters such as AC/DC rectifiers, DC/AC inverters and DC/DC choppers in the system. The incursion of numerous power electronic devices leads to complex network and also causes power quality and stability issues. The current harmonics may cause unbalance in the aircraft electric power system and severe voltage distortion. Thus, the active filters can compensate the harmonics, improves the power factor and work as a reactive power compensator, thus in turn afford power quality enhancement of the system. This work proposes the use of a five level cascaded H-bridge VSI with an improved current control and a suitably developed modulation strategy to reduce harmonics in air craft system.

Keywords


Power Quality, Active Power Filter, Fuzzy PI controller, Harmonics Compensation.