Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Evaluation of Anti-Bacterial and Anti-Fungal Activity of Steri-Gen


Affiliations
1 Department of Microbiology, Government Medical College, Akola, Maharashtra, India
     

   Subscribe/Renew Journal


Background: Antiseptics are essential part of infection control practices. Faith Innovations has launched Steri-Gen Disinfectant Generation System based on the novel Sterigen technology. The system generates neutral pH, stable Hypochlorous acid (HClO) along with a mixture of oxidants like hydroxyl anion, peroxide anion, oxonium ion etc. This mixture of oxidants and HClO is known as Sterigen Solution. Sterigen Solution is a high level disinfectant produced using water, Sterigen- C and electricity.

Aim: To evaluate bactericidal&fungicidal action of Sterigen solution.

Material & method: The solitary isolates of multi drug resistant test organisms Methicillin Resistant S. aureus (MRSA), K. pneumoniae, P. mirabilis, Ps. aeruginosa, E. coli&C. albicans isolated from hospitalized patients were included in the study. The disinfectant was evaluated by Suspension test qualitatively with contact time-1,3&5 minutes. Tests were performed in duplicate to ascertain reproducibility. Pre-fumigation and Post-fumigation decrease in bacterial load was also assessed.

Result: Sterigen solution was an effective anti-bacterial and anti-fungal agent for hospital use in dilutions upto 1:3.


Subscription Login to verify subscription
User
Notifications
Font Size


  • Rutala, W. A. 1995. APIC guidelines for selection and use of disinfectants. Am. J. Infect. Control 23:313–342
  • Dettenkofer M, Wenzler S, Amthor S, Motschall E, Daschner. FD. Does disinfection of environmental surfaces influence nosocomial infection rates? A systematic review. Am JInfect Control 2004; 32: 84-89.
  • http://www.faithbiotech.in/sterigen.html
  • Aggarwal.R,Goel.N,Chaudhary.U,Kumar.V,Ranjan.K.Evaluation of microbiocidal activity of superoxidized water on hospital isolates.IJPM.2010.53(4):757-59.
  • Patwardhan.N .Hospital-Associated infections Epidemiology, Prevention and control. Jaypee publications.
  • Selkon JB, Babb JR, Morris, R. Evaluation of the antimicrobial activity of a new super-oxidized water, Sterilox, for the disinfection of endoscopes. J Hosp Infect 1999; 41: 59-70.
  • Shetty N, Srinivasan S, Holton J, Ridgway G. Evaluation of microbiocidal activity of a new disinfectant: Sterilox 2500 against Clostridium difficile spores, Helicobacter pylori, vancomycin resistant Enterococcus species, Candida albicans and several Mycobacterium species. J Hosp Infect 1999; 41:101-105

Abstract Views: 853

PDF Views: 0




  • Evaluation of Anti-Bacterial and Anti-Fungal Activity of Steri-Gen

Abstract Views: 853  |  PDF Views: 0

Authors

K. Ostwal
Department of Microbiology, Government Medical College, Akola, Maharashtra, India
R. Karyakarte
Department of Microbiology, Government Medical College, Akola, Maharashtra, India
A. Goenka
Department of Microbiology, Government Medical College, Akola, Maharashtra, India
P. Giri
Department of Microbiology, Government Medical College, Akola, Maharashtra, India

Abstract


Background: Antiseptics are essential part of infection control practices. Faith Innovations has launched Steri-Gen Disinfectant Generation System based on the novel Sterigen technology. The system generates neutral pH, stable Hypochlorous acid (HClO) along with a mixture of oxidants like hydroxyl anion, peroxide anion, oxonium ion etc. This mixture of oxidants and HClO is known as Sterigen Solution. Sterigen Solution is a high level disinfectant produced using water, Sterigen- C and electricity.

Aim: To evaluate bactericidal&fungicidal action of Sterigen solution.

Material & method: The solitary isolates of multi drug resistant test organisms Methicillin Resistant S. aureus (MRSA), K. pneumoniae, P. mirabilis, Ps. aeruginosa, E. coli&C. albicans isolated from hospitalized patients were included in the study. The disinfectant was evaluated by Suspension test qualitatively with contact time-1,3&5 minutes. Tests were performed in duplicate to ascertain reproducibility. Pre-fumigation and Post-fumigation decrease in bacterial load was also assessed.

Result: Sterigen solution was an effective anti-bacterial and anti-fungal agent for hospital use in dilutions upto 1:3.


References