Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

UV Spectrophotometric Method Development and Validation of Lornoxicam Loaded Solid SMEDDS


Affiliations
1 Department of Quality Assurance Techniques, R. G. Sapkal College of Pharmacy, Anjaneri, Nashik, India
2 Department of Pharmaceutical Chemistry, R. G. Sapkal College of Pharmacy, Anjaneri, Nashik, India
     

   Subscribe/Renew Journal


Analytical methods development and validation play important roles in the discovery, development, and manufacture of pharmaceuticals. Simple, precise and accurate UV spectroscopic method has been developed and validated for estimation of Lornoxicam loaded solid SMEDDS. UV spectroscopic method which is based on measurement of absorption of UV light, the spectra of Lornoxicam SMEDDS in 0.1N NaOHshowed maximum wavelength at 375nm and calibration curve were plotted over the concentrations ranging from 5-50ug/ml of Lornoxicam SMEDDS with correlation coefficient 0.999 validation was performed as per ICH Q2 (R1) guidelines for linearity, accuracy, precision and recovery. The proposed method was validated.

Keywords

Lornoxicam, 0.1N NaOH, Spectrophotometer and Validation.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 281

PDF Views: 2




  • UV Spectrophotometric Method Development and Validation of Lornoxicam Loaded Solid SMEDDS

Abstract Views: 281  |  PDF Views: 2

Authors

Pankaj P. Pawar
Department of Quality Assurance Techniques, R. G. Sapkal College of Pharmacy, Anjaneri, Nashik, India
Dipti G. Phadtare
Department of Pharmaceutical Chemistry, R. G. Sapkal College of Pharmacy, Anjaneri, Nashik, India

Abstract


Analytical methods development and validation play important roles in the discovery, development, and manufacture of pharmaceuticals. Simple, precise and accurate UV spectroscopic method has been developed and validated for estimation of Lornoxicam loaded solid SMEDDS. UV spectroscopic method which is based on measurement of absorption of UV light, the spectra of Lornoxicam SMEDDS in 0.1N NaOHshowed maximum wavelength at 375nm and calibration curve were plotted over the concentrations ranging from 5-50ug/ml of Lornoxicam SMEDDS with correlation coefficient 0.999 validation was performed as per ICH Q2 (R1) guidelines for linearity, accuracy, precision and recovery. The proposed method was validated.

Keywords


Lornoxicam, 0.1N NaOH, Spectrophotometer and Validation.