Open Access
Subscription Access
Open Access
Subscription Access
ICH Guideline Practice- A Validated Stability- Indicating HPLC Method for the Determination of Efavirenz in Dosage Form
Subscribe/Renew Journal
A simple, precise, accurate and new stability-indicating reversed-phase high-performance liquid chromatographic (RPHPLC) method was developed and validated as per International Conference on Harmonisation (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use guidelines to determine efafirenz in tablet dosage form. The drug was successfully eluted at 6.264 min by mixture of ammonium dihydrogen phosphate buffer, acetonitrile and triethylamine (30:70:1) on C18 column (150 mm × 4.6 mm, 5 μm) at the flow of 1.5 ml/min. Drug content was determined in between 99.79% and 100.33% with standard deviation of 0.217. The validated RP-HPLC method may be successfully applied for assay, dissolution studies, bio-equivalence studies, as well as routine analysis in pharmaceutical industries.
Keywords
RP-HPLC, Efavirenz, ICH.
Subscription
Login to verify subscription
User
Font Size
Information
Abstract Views: 249
PDF Views: 0