Preparation and Analytical Studying of Ligand (NO2BTAHB) with (Cu) - Ion


Affiliations
1 Department of Chemistry, Collage of Science, University of Kufa, Kufa, Iraq
     

   Subscribe/Renew Journal


In this study, organic reagent 2-[6-Nitro-2-benzothiazolylazo]-4-hydroxy benzoic acid (NO2BTAHB) was synthesized. A sensitive and selective spectrophotometric method was proposed for the rapid determination of Cu(II) using (NO2BTAHB) reagent. The reaction between Cu(II) and (NO2BTAHB) reagent is instantaneous at pH=6.0 and the absorbance remains stable for over 24 hrs.

The Method allows for the determination of Cu(II) over the range (0.1-6.0) μg.ml-1, with molar absorptivity of (7.45 x 10+3)l.mol-1.cm-1 and a detection limit of 0.0245 μg.ml-1. Recovery and relative error values of precision and accuracy of method were found to be R.S.D=1.7% , Re=98.6% , and Erel=-1.4%. The properties of complex was studied and show; (M:R) ratio was 1:2 at pH=6.0 ,and the stability constant of 7.796 x 10+9L2.mol-2. The interferences of ions (Ni2+, CrO2-, Ca2+, pb2+, Cu+2, WO4-2, MO4-2, Co2+, Mg2+, Cd2+, Ba2+, Bi3+) and masking agents effect on absorbance were studied.


Keywords

Human, Purified, Nutrient, Toxic, Level.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 260

PDF Views: 0




  • Preparation and Analytical Studying of Ligand (NO2BTAHB) with (Cu) - Ion

Abstract Views: 260  |  PDF Views: 0

Authors

Aqeel Mahdi Jreo
Department of Chemistry, Collage of Science, University of Kufa, Kufa, Iraq

Abstract


In this study, organic reagent 2-[6-Nitro-2-benzothiazolylazo]-4-hydroxy benzoic acid (NO2BTAHB) was synthesized. A sensitive and selective spectrophotometric method was proposed for the rapid determination of Cu(II) using (NO2BTAHB) reagent. The reaction between Cu(II) and (NO2BTAHB) reagent is instantaneous at pH=6.0 and the absorbance remains stable for over 24 hrs.

The Method allows for the determination of Cu(II) over the range (0.1-6.0) μg.ml-1, with molar absorptivity of (7.45 x 10+3)l.mol-1.cm-1 and a detection limit of 0.0245 μg.ml-1. Recovery and relative error values of precision and accuracy of method were found to be R.S.D=1.7% , Re=98.6% , and Erel=-1.4%. The properties of complex was studied and show; (M:R) ratio was 1:2 at pH=6.0 ,and the stability constant of 7.796 x 10+9L2.mol-2. The interferences of ions (Ni2+, CrO2-, Ca2+, pb2+, Cu+2, WO4-2, MO4-2, Co2+, Mg2+, Cd2+, Ba2+, Bi3+) and masking agents effect on absorbance were studied.