Study of Frequency and Concentration Dependence of Ultrasonic Attenuation of Nio Nanoparticle Embedded in Polyvinilidyne Fluoride


Affiliations
1 Department of Physics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah-711103, India
 

In this work the frequency dependent attenuation coefficient of NiO embedded polyvinilidyne fluoride (PVDF) for different concentrations has been studied by the ultrasonic transmission technique. The NiO nanoparticles have been prepared by hydrothermal route and the sample was stirred with PVDF solution (by using DMF as solvent) and the thin film was prepared by slow evaporation method. The sample having different concentrations as well as neat PVDF film were taken for ultrasonic study. Then the amplitude versus time data has been collected from the ultrasonic pulsar/receiver instrument USLT 2000 by A-scan process. The readings are taken by using the transducer of central frequency 500 kHz. To convert this data in time-domain to frequency- domain, Fast Fourier transformation (FFT) has been done. From the result, the ultrasonic absorption increases with the increase of concentration of the sample for a given frequency and this is obvious as the number density of the scatterer increases. Ultrasonic absorption increases with the increase of frequency for a given concentration of the sample as the scattering increases in the Rayleigh region (λ>> a, the particle size).

Keywords

Nanoparticle, Ultrasonic Absorption, FFT.
User
Notifications
Font Size

  • Jahan N., Mighri F., Rodrigue D. and A. Ajji, Enhanced electroactive β-phase in three phase PVDF/CaCO3/ nanoclay composites: Effect of micro-CaCO3 and uniaxial stretching, J. Appl. Polym. Sci., 134 (2017) 44940 (11 pp.).
  • Dutta B., Kar E., Bose N. and Mukherjee S., Significant enhancement of the electroactive β-phase of PVDF by incorporating hydrothermally synthesized copper oxide nanoparticles, RSC Adv., 5 (2015) 105422.
  • Dutta B., Kar E., Bose N. Mukherjee N. and Mukherjee S., Poly (vinylidene fluoride)/submicron graphite platelet composite: A smart, lightweight flexible material with significantly enhanced β polymorphism, dielectric and microwave shielding properties. Euro. Poly. J., 90 (2017) 442-455.
  • Kim N.K., Richard J.T.L., Stoyko F., Kean A. and Bhattacharyya D., Nanofibrillar Poly (vinylidene fluoride): Preparation and Functional Properties, International J. Poly. Mater. Poly. Biomater., 63 (2013) 23-32.
  • Kar E., Bose N., Das S., Mukherjee N. and Mukherjee S., Enhancement of electroactive β-phase crystallization and dielectric constant of PVDF by incorporating GeO2 and SiO2 nanoparticles, Phys. Chem. Chem. Phys., 17 (2015) 22784-22798.
  • Martins P., Lopes A.C. and Lanceros-Mendez S., Electroactive phases of poly (vinylidene fluoride): determination, processing and applications, Prog. Polym. Sci., 39 (2014) 683-706.
  • Chang Y.M., Lee J.S. and Kim K.J., Heartbeat monitoring technique based on corona-poled PVDF film sensor for smart apparel application. Solid State Phenom., 124 (2007) 299-302.
  • Lovinger A.J., Ferroelectric polymers, Science, 220 (1983) 1115-1121.
  • Fukada E., History and recent progress in piezoelectric polymers, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 47 (2000) 1277-1290.
  • He F., Fan J. and Lau S. Thermal, mechanical and dielectric properties of graphite reinforced poly (vinylidene fluoride) composites. Polym. Testing, 27 (2008) 964-970.
  • Balitskii D.B., Sil'vestrova O. Yu., Balitskii V.S., Pisarevskii Yu. V., Pushcharovskii D. Yu. and Philippot E., Elastic, piezoelectric, and dielectric properties of α-GeO2 single crystals. Crystallogr. Rep. 45 (2000) 145-147.
  • Kozhushkoa, V.V., Paltaufa G., Krenna H., Scheriaub S. and Pippanb R., Attenuation of ultrasound in severely plastically deformed nickel. NDT & E International, 44 (2011) 261-266.
  • Saniie J. and Bilgutay N.M., , Quantitative grain size evaluation using ultrasonic backscattered echoes, J. Acoust. Soc. Am. 80 (1986) 1816-1824.
  • Sarpun I.H. and Unal R., Mean grain size determination in marbles by ultrasonic techniques. ECNDT, (2006)-Fr.1.7.4.
  • Hukkanen E.J. and Braatz R.D., Measurement of particle size distribution in suspension polymerization using in situ laser backscattering, Sens. Actuators, B 96 (2003) 451-459
  • Beecham D., Ultrasonic scatter in metals: its properties and its application to grain size determination, Ultrasonics, 4 (1966) 67-76.
  • Kulkarni S.S. and Khadke U.V., Effect of solvents on the ultrasonic velocity and acoustic parameters of polyvinylidene fluoride solutions. Ind. J. Mater. Sci., (2016) 9582582 (6 pp.).
  • Keith A.W., Timothy A.S., Gary R.F., Ernest L.M., Francis C., Ernest J.F., Christopher S.H., Soo K.B., Paul L., William D. Jr O , Michael L.O., Balasundar I.R., Kirk S.K., Thaddeus A.W. and Jian R.Y., Inter laboratory comparison of ultrasonic backscatter coefficient measurements from 2 to 9 MHz. J. Ultrasound Med., 24 (2005) 1235-1250.

Abstract Views: 278

PDF Views: 3




  • Study of Frequency and Concentration Dependence of Ultrasonic Attenuation of Nio Nanoparticle Embedded in Polyvinilidyne Fluoride

Abstract Views: 278  |  PDF Views: 3

Authors

Chayan K. Karmakar
Department of Physics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah-711103, India
Biplab Dutta
Department of Physics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah-711103, India
Sampad Mukherjee
Department of Physics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah-711103, India

Abstract


In this work the frequency dependent attenuation coefficient of NiO embedded polyvinilidyne fluoride (PVDF) for different concentrations has been studied by the ultrasonic transmission technique. The NiO nanoparticles have been prepared by hydrothermal route and the sample was stirred with PVDF solution (by using DMF as solvent) and the thin film was prepared by slow evaporation method. The sample having different concentrations as well as neat PVDF film were taken for ultrasonic study. Then the amplitude versus time data has been collected from the ultrasonic pulsar/receiver instrument USLT 2000 by A-scan process. The readings are taken by using the transducer of central frequency 500 kHz. To convert this data in time-domain to frequency- domain, Fast Fourier transformation (FFT) has been done. From the result, the ultrasonic absorption increases with the increase of concentration of the sample for a given frequency and this is obvious as the number density of the scatterer increases. Ultrasonic absorption increases with the increase of frequency for a given concentration of the sample as the scattering increases in the Rayleigh region (λ>> a, the particle size).

Keywords


Nanoparticle, Ultrasonic Absorption, FFT.

References