Open Access Open Access  Restricted Access Subscription Access

Feasibility of Reinforced Concrete Monolothic Beam Column Joints in Different Seismic Zones


Affiliations
1 Senior Engineer, 53rd Design & Drafting, Street No. 4, Basti Ram Ji ki Bari, Bohrwadi, Udaipur - 313 001, Rajasthan, India

   Subscribe/Renew Journal


The present paper emphasizes the design of R.C. monolithic beam-column joints for strength criteria and to find out feasibility of the structure designed for Zone 2 and Zone 5 as per IS1893(Part1):2002, incorporating ductility provisions of IS13920:1993. For this research a moment resisting RCC frame is modeled and analyzed for above mentioned seismic zones. After analyzing, resultant frames are then designed as per IS 456. An Internal Beam Column Joint form first, third, and top floor is selected and designed manually for nominal shear strength so as to compare it with shear developed in the same joints provided by the software. The software of choice for this paper is ETABS.

Keywords

Beam Column Joints, ETABS, Frame Structure, Joint Shear, Moment Resisting Frame, R.C.C. Design.

Manuscript Received : April 28, 2021; Revised : August 12, 2021; Accepted : August 18, 2021. Date of Publication : November 5, 2021.

User
Subscription Login to verify subscription
Notifications
Font Size

  • S. R. Uma and A. M. Prasad, “Seismic behavior of beam column joints in reinforced concrete moment resisting frames,†Indian Institute of Technol., Chennai. [Online]. Available: https://www.iitk.ac.in/nicee/IITK-GSDMA/EQ31.pdf
  • K. F. Sarsam and M. E. Phipps, “The shear design of in situ reinforced concrete beam column joints subjected to monotonic loading,†Magazine of Concrete Res., vol. 37, no. 130, pp. 16–28, 1985. https://doi.org/10.1680/macr.1985.37.130.16
  • Plain and reinforced concrete – code of practice, IS 456: 2000.
  • R. T. Leon, “Shear strength and hysteretic behavior of beam-column joints,†ACI Structural J., vol. 87, no.1, pp. 3–11, 1990.
  • R. K. Ingle and S. K. Jain, “Explanatory examples for ductile detailing of RC buildings,†Indian Institute of Technol., Kanpur. [Online]. Available: https://www.iitk.ac.in/nicee/IITK-GSDMA/EQ22.pdf
  • Recommendations for design of beam-column-joints in monolithic reinforced concrete structures. American Concrete Institute, ACI 352R–02, ACI- ASCE, Committee 352, Detroit, 2002.
  • Indian standard code of practice for ductile detailing of concrete structures subjected to seismic forces, IS 13920:1993.
  • Criteria for earthquake resistant design of structures, IS 1893 (Part1): 2002.
  • A. Wagla Wala, “The effect of shear on reinforced concrete beam column joints in various seismic zones,†Dissertation, Masters in Structural Eng., Department of Structural Eng., Faculty of Eng. and Architecture, M. B. M. Eng. College, Jai Narain Vyas University, Jodhpur, 2013.
  • M. Poudel and M. Poudel, “A study of the seismic performance of square & L-shaped buildings resting on various angles of hill slopes,†AMC Indian Journal of Civil Engineering, vol. 4, no. 1, 17–28, 2021. [Online]. Available: http://dx.doi.org/10.17010/ijce%2F2021%2Fv4i1%2F160807
  • A. Daftardar and A. K. Narayanan, “Seismic Retrofitting of Concrete Structuresâ€, AMC Indian Journal of Civil Eng., vol. 1, no. 1, 7–13, 2018. [Online]. Available: http://dx.doi.org/10.17010/ijce%2F2018%2Fv1i1%2F120882
  • Code of practice for design loads (other than earthquake) for building and structures, IS 875:1987.

Abstract Views: 109

PDF Views: 0




  • Feasibility of Reinforced Concrete Monolothic Beam Column Joints in Different Seismic Zones

Abstract Views: 109  |  PDF Views: 0

Authors

Aqeel Ali Shams Wagla Wala
Senior Engineer, 53rd Design & Drafting, Street No. 4, Basti Ram Ji ki Bari, Bohrwadi, Udaipur - 313 001, Rajasthan, India

Abstract


The present paper emphasizes the design of R.C. monolithic beam-column joints for strength criteria and to find out feasibility of the structure designed for Zone 2 and Zone 5 as per IS1893(Part1):2002, incorporating ductility provisions of IS13920:1993. For this research a moment resisting RCC frame is modeled and analyzed for above mentioned seismic zones. After analyzing, resultant frames are then designed as per IS 456. An Internal Beam Column Joint form first, third, and top floor is selected and designed manually for nominal shear strength so as to compare it with shear developed in the same joints provided by the software. The software of choice for this paper is ETABS.

Keywords


Beam Column Joints, ETABS, Frame Structure, Joint Shear, Moment Resisting Frame, R.C.C. Design.

Manuscript Received : April 28, 2021; Revised : August 12, 2021; Accepted : August 18, 2021. Date of Publication : November 5, 2021.


References





DOI: https://doi.org/10.17010/ijce%2F2021%2Fv4i2%2F166722