Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Evaluation of Implant Stability of Supported Mandibular Overdenture Retained by Telescopic Crowns Over Screw Retained and Self-locking Conical Abutment Connection


Affiliations
1 Minia University, Egypt
2 Department and Head of the Department. Minia University, Egypt
3 Department and Vice President, Sinai University, Egypt
     

   Subscribe/Renew Journal


Background and Objective: Long-term success of dental implants depends on implant abutment connection. This prospective study aims to assess the implant stability of self locking conical connection and traditional platform implant abutment connection with mandibular telescopic supported overdenture.

Material and Method: This study is a randomized controlled study included twelve completely edentulous patients selected from the Outpatient Clinic of the Prosthodontics Department, Faculty of Dentistry, Minia University.Two ischolar_main form implants were inserted in canine area bilaterally in each patientone is self -locking implant abutment connection while the other is traditional platform. Telescopic overdenture was constructed over the two implants. The stability was evaluated at 3, 6, 9 and 12 months. The collected data were analyzed by SPSS program version 20 with considering statistical significance when P value<0.05.

Results: There was no significant difference in implant stability regarding mean implant index when evaluated at delivery and various intervals with self locking conical implant abutment connection. While with traditional implant abutment connection there was significant difference in implant stability when evaluated at delivery and 6 months interval.

Conclusion: The self locking conical implant abutment has more stability rather than traditional platform implant. This is may be explained by that the self locking conical implant abutment interface optimize the ability of an implant-to-abutment joint to resist bending forces and micromotion increasing implant secondary stability.


Keywords

Stability, Telescopic Over Denture, Self Locking Conical Connection Implants.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 147

PDF Views: 0




  • Evaluation of Implant Stability of Supported Mandibular Overdenture Retained by Telescopic Crowns Over Screw Retained and Self-locking Conical Abutment Connection

Abstract Views: 147  |  PDF Views: 0

Authors

Shaima’a Ahmed Radwan
Minia University, Egypt
Ahmed Gamal Ahmed Hassan
Minia University, Egypt
Emad M. T. Agamy
Department and Head of the Department. Minia University, Egypt
Gehan Fekry Mohammed
Department and Vice President, Sinai University, Egypt

Abstract


Background and Objective: Long-term success of dental implants depends on implant abutment connection. This prospective study aims to assess the implant stability of self locking conical connection and traditional platform implant abutment connection with mandibular telescopic supported overdenture.

Material and Method: This study is a randomized controlled study included twelve completely edentulous patients selected from the Outpatient Clinic of the Prosthodontics Department, Faculty of Dentistry, Minia University.Two ischolar_main form implants were inserted in canine area bilaterally in each patientone is self -locking implant abutment connection while the other is traditional platform. Telescopic overdenture was constructed over the two implants. The stability was evaluated at 3, 6, 9 and 12 months. The collected data were analyzed by SPSS program version 20 with considering statistical significance when P value<0.05.

Results: There was no significant difference in implant stability regarding mean implant index when evaluated at delivery and various intervals with self locking conical implant abutment connection. While with traditional implant abutment connection there was significant difference in implant stability when evaluated at delivery and 6 months interval.

Conclusion: The self locking conical implant abutment has more stability rather than traditional platform implant. This is may be explained by that the self locking conical implant abutment interface optimize the ability of an implant-to-abutment joint to resist bending forces and micromotion increasing implant secondary stability.


Keywords


Stability, Telescopic Over Denture, Self Locking Conical Connection Implants.