Surface Wear and Distortion of RaCe, Protaper and K3 Endodontics Instruments-An SEM in Vitro Study


Affiliations
1 Professor, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
2 Private Practitioner, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
3 Second Year PG Student, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
4 Reader, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
     

   Subscribe/Renew Journal


A Comparative evaluation of surface wear and distortion of ProTaper, RaCe and K3 nickel-titanium rotary instruments was done using resin blocks with 20 degrees curvature. Three groups of four samples were evaluated for spiral distortion and surface wear after instrumentation. The deformation and fracture of F1 of ProTaper, 0.06 tapers RaCe and were photographically recorded SEM 250X using magnification. It was evident from the scores obtained and SEM pictures analysed that ProTaper instruments exhibited significantly higher degree of spiral distortion and surface wear compared to both RaCe and K3, with no statistical variation between the latter two systems.

Keywords

Surface Wear, Distortion and Cyclic Fatigue.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 118

PDF Views: 0




  • Surface Wear and Distortion of RaCe, Protaper and K3 Endodontics Instruments-An SEM in Vitro Study

Abstract Views: 118  |  PDF Views: 0

Authors

Prakash Venkatachalam
Professor, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
Rama Krishna
Private Practitioner, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
Devakar Rajendran
Second Year PG Student, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
Geethapriya Nagarajan
Reader, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
Venkatesh Alagarsamy
Professor, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India
Anuradha Balasubramaniam
Reader, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India

Abstract


A Comparative evaluation of surface wear and distortion of ProTaper, RaCe and K3 nickel-titanium rotary instruments was done using resin blocks with 20 degrees curvature. Three groups of four samples were evaluated for spiral distortion and surface wear after instrumentation. The deformation and fracture of F1 of ProTaper, 0.06 tapers RaCe and were photographically recorded SEM 250X using magnification. It was evident from the scores obtained and SEM pictures analysed that ProTaper instruments exhibited significantly higher degree of spiral distortion and surface wear compared to both RaCe and K3, with no statistical variation between the latter two systems.

Keywords


Surface Wear, Distortion and Cyclic Fatigue.