Open Access Open Access  Restricted Access Subscription Access
Open Access Open Access Open Access  Restricted Access Restricted Access Subscription Access

Comparative Analysis of Densitometric Tonal Value Increase and Colorimetrie Tonal Value Increase


Affiliations
1 Creation Offset Press, Ernakulam, Kerala, India
     

   Subscribe/Renew Journal


The tonal value increase in printing denotes the dot gain that should he considered at the time of print quality assessment. That is indirectly connected to other print quality parameters such as solid ink density, print contrast etc. Tonal value increase is higher in middle tone patches of process colors. The TVI can he considered both colorimetrically and densitometrically. The use of two cyan color inks has same tonal value but there will be an apparent hue shift. The densitomeric TVI only consider the process control and colorimetric TVI combines both process control and image appearance. The Densitometric TVI is measured in M3 mode and Colorimetric TVI is based on MO mode. This research paper shows the densitometric TVI values are higher than the colorimetric TVI. The black color patches shows higher delta TVI and yellow color patches shows lowest delta TVI.

Keywords

Light Fastness, Delta E, UV Absorbers.
Subscription Login to verify subscription
User
Notifications
Font Size


Abstract Views: 277

PDF Views: 2




  • Comparative Analysis of Densitometric Tonal Value Increase and Colorimetrie Tonal Value Increase

Abstract Views: 277  |  PDF Views: 2

Authors

C. Dinesh
Creation Offset Press, Ernakulam, Kerala, India

Abstract


The tonal value increase in printing denotes the dot gain that should he considered at the time of print quality assessment. That is indirectly connected to other print quality parameters such as solid ink density, print contrast etc. Tonal value increase is higher in middle tone patches of process colors. The TVI can he considered both colorimetrically and densitometrically. The use of two cyan color inks has same tonal value but there will be an apparent hue shift. The densitomeric TVI only consider the process control and colorimetric TVI combines both process control and image appearance. The Densitometric TVI is measured in M3 mode and Colorimetric TVI is based on MO mode. This research paper shows the densitometric TVI values are higher than the colorimetric TVI. The black color patches shows higher delta TVI and yellow color patches shows lowest delta TVI.

Keywords


Light Fastness, Delta E, UV Absorbers.