A Study on the Size of Bore on Signal to Noise Ratio (SNR) in Magnetic Resonance Imaging (MRI)


Affiliations
1 Department of Radiology Science, Far East University, Chungbuk, Korea, Republic of
 

Background/Objectives: An objective of this study is to analyze the size of bore on signal to noise ratio in magnetic resonance imaging. Methods/Statistical Analysis: During this process, the magnetic field also shows irregularity due to the environmental factors. Therefore in this study, magnetic field non-uniformity according to the bore size of MRI will be examined as well as the influence on the image through SNR measurement. Findings: Avanto with bigger bore size has shown higher SNR value, and especially, it has shown 6 times or greater difference in TSE(Turbo Spin Echo) technique. Improvements: It would be imperative to conduct a test with a small bore size and a uniform magnet when the MRI test failure rate is high due to claustrophobia.

Keywords

Bore size, Claustrophobia, Magnetic field, Magnetic Resonance Image (MRI), Pulse sequence, Signal to Noise Ratio (SNR).
User

Abstract Views: 152

PDF Views: 0




  • A Study on the Size of Bore on Signal to Noise Ratio (SNR) in Magnetic Resonance Imaging (MRI)

Abstract Views: 152  |  PDF Views: 0

Authors

Dong-Hee Hong
Department of Radiology Science, Far East University, Chungbuk, Korea, Republic of
Joon-Koo Choi
Department of Radiology Science, Far East University, Chungbuk, Korea, Republic of
Gha-Jung Kim
Department of Radiology Science, Far East University, Chungbuk, Korea, Republic of
Hyeong-Gyun Kim
Department of Radiology Science, Far East University, Chungbuk, Korea, Republic of

Abstract


Background/Objectives: An objective of this study is to analyze the size of bore on signal to noise ratio in magnetic resonance imaging. Methods/Statistical Analysis: During this process, the magnetic field also shows irregularity due to the environmental factors. Therefore in this study, magnetic field non-uniformity according to the bore size of MRI will be examined as well as the influence on the image through SNR measurement. Findings: Avanto with bigger bore size has shown higher SNR value, and especially, it has shown 6 times or greater difference in TSE(Turbo Spin Echo) technique. Improvements: It would be imperative to conduct a test with a small bore size and a uniform magnet when the MRI test failure rate is high due to claustrophobia.