Open Access Open Access  Restricted Access Subscription Access

Case Study on Double Tube Stub Columns


Affiliations
1 Civil Engineering, SSN College of Engineering, Mylapore, Chennai – 600004, Tamil Nadu, India
 

Objectives: Experimental study on Double tube Stub column is presented in this paper. Methods/Analysis: The behavior of the concrete infilled double tube stub columns was investigated. Three different strength of concrete namely 30 Mpa, 40 Mpa and 50 Mpa were used to fill the column specimens. To avoid buckling of the test specimen, diameter to thickness ratio was 33.3 and length to Diameter ratio was 3. This value was used for the entire test specimen. Findings: The failure modes of double tube column, load-deflection relation and load- strain relation were presented. Application: From the experimental study it is found that column strength increases due to the presence of additional inner mild steel tube for column having different outer tube materials namely Aluminium (Al), Stainless steel (SS) and Mild steel (MS). From the result it was observed that the presence of inner tube is more beneficial for columns with stainless steel and aluminium as outer tube if the strength of the concrete is less.
User

  • Zhao XL, Grzebieta RH. Strength and ductility of concrete filled double skin (SHS inner and SHS outer) tubes. Thin-Walled Structures. 2002; 40(10):815–33. Crossref.
  • Elchalakani M, Zhao XL, Grzebieta RH. Tests on concrete filled double-skin (CHS outer and SHS inner) composite short columns under axial compression. Thin-Walled Structures. 2002; 40(5):415–41. Crossref.
  • Tao Z, Han LH, Zhao XL. Behaviour of concrete- filled double skin (CHS inner and CHS outer) steel tubular stub columns and beam-columns. Journal of construction steel research. 2004; 60(8):1129–58.
  • Dabaon M, Khoriby SE, Boghdadi ME, Mostafa FH. Confinement effect of stiffened and unstiffened concrete-filled stainless steel tubular stub columns. Journal of Constructional Steel Research. 2009; 65(8):1846–54. Crossref.
  • Uenaka K, Kitih H, Sonoda K. Concrete filled double skin circular stub columns under compression. Thin Walled Structures. 2010; 48(1):19–24. Crossref.
  • Han LH, Ren QX, Li W. Tests on stainless steel-concrete carbon steel double skin tubular columns. Journal of Construction Steel Research. 2011; 67(3):437–52.
  • Hassanein MF, Kharoob OF. Analysis of circular concrete-filled double skin tubular slender columns with external stainless steel tubes. Thin Walled Structures. 2014; 79:23– 37. Crossref.
  • Wang F, Young B, Gardner L. Experimental investigation of concrete filled double skin tubular stub columns with stainless steel outer tubes. 8th International Conference on Steel and Aluminium Structures. Hong Kong, China; 2016. p. 1–15.
  • Xin Yu, Tao Z, Tia YS. Effect of different types of aggregates on the performance of concrete- filled steel tubular stub columns. Materials and Structures. 2015; 49(9):23–37.
  • Yu X, Tao Z, Song TY. Behaviour of concrete filled steel tubular stub columns with different aggregates. 11th International Conference on Advances in Steel and Concrete Composite Structures. At Beijing; 2015. p. 1–9.
  • Li W, Wang D, Han LH. Behavior of grout filled double skin steel tubes under compression and bending: experiments. Thin Walled Structures. 2017; 116:307–19. Crossref.
  • Wang ZB, Tao Z, Yu Q. Axial compressive behavior of concrete filled double tube stub columns with stiffeners. Thin Walled Structures. 2017; 120(11):91–104. Crossref.

Abstract Views: 230

PDF Views: 0




  • Case Study on Double Tube Stub Columns

Abstract Views: 230  |  PDF Views: 0

Authors

S. Ramanagopal
Civil Engineering, SSN College of Engineering, Mylapore, Chennai – 600004, Tamil Nadu, India

Abstract


Objectives: Experimental study on Double tube Stub column is presented in this paper. Methods/Analysis: The behavior of the concrete infilled double tube stub columns was investigated. Three different strength of concrete namely 30 Mpa, 40 Mpa and 50 Mpa were used to fill the column specimens. To avoid buckling of the test specimen, diameter to thickness ratio was 33.3 and length to Diameter ratio was 3. This value was used for the entire test specimen. Findings: The failure modes of double tube column, load-deflection relation and load- strain relation were presented. Application: From the experimental study it is found that column strength increases due to the presence of additional inner mild steel tube for column having different outer tube materials namely Aluminium (Al), Stainless steel (SS) and Mild steel (MS). From the result it was observed that the presence of inner tube is more beneficial for columns with stainless steel and aluminium as outer tube if the strength of the concrete is less.

References





DOI: https://doi.org/10.17485/ijst%2F2018%2Fv11i21%2F122490